ByTenantsByTenants home

834 Hart Street, Brooklyn, NY 11237

Built 1931 · 3-story walk-up · 6 apartments

12 immediately hazardous violations open. 23 open in all. On the state's rent-stabilization list for 2024.

Tenant reviews
None yetLived here? Reviews open soon.
Open violations
2312 · 10 · 1
Public record
Updated todayFrom the city’s own data (, 311, the courts), refreshed nightly.

Violations issued each year

Violations issued each year
YearHazardousNon-hazardous
202200
202300
202400
202500
2026 so far141

Plus 138 violations from 2000 to 2021. Counted when issued, whether open or fixed since. Paperwork left out.

See every violation
Found most often since 2022
  • Leaks and plumbing 4
  • Fire and safety equipment 4
  • Walls and ceilings 4
Open per apartment
3.8 (23 open across 6 apartments)
Inspector last found a problem
29 Sept 2026 (visits that find nothing are not published)
What do these labels mean?
Tenant-reported
A resident's firsthand account of living here, moderated before it publishes, and labelled with whether we verified they lived there.
Official violation
A city inspector visited and recorded a code violation. HPD's own words, and its own hazard class.
Public complaint
A complaint somebody made to a city system, through HPD or 311. A report, not a finding: nobody has necessarily inspected it.
Public filing
A permit, a registration, a bedbug report: a document the owner filed with the city because the law requires it.
Court record
A Housing Court case HPD brought against the owner, or an eviction a city marshal carried out. A court's record: a case is an allegation until it ends in a finding.
Insufficient data
Not enough current information here to infer a pattern either way.

Tenant reviews

Tenant-reported

No tenant reviews yet. Lived here? Be the first.

Nothing above this section came from a tenant. It is all filed by the city, which means it only holds what somebody reported and an inspector wrote down, not what it is actually like to live here.

Not open yet. Reviews open when this neighbourhood does.

Heat season

No heat or hot-water complaints or violations were recorded here last winter (2025–26). That is the city's record: it only holds what somebody reported.

WinterDaysComplaintsViolations
2025–26000

The rules, 1 October to 31 May: from 6am to 10pm, when it is below 55°F outside, the apartment must be at least 68°F; overnight it must be at least 62°F whatever the weather. Hot water must be at least 120°F all year. A tenant without heat can report it to 311.

Rent stabilization

Public filing

The owner registered at least one rent-stabilized apartment here with the state for 2024. The list does not say which apartments, or how many.

Source: Rent Guidelines Board building list, from the state's 2024 registrations. To know about one apartment, a tenant can ask the state for its rent history through Ask HCR.

City violations

Official violation

Immediately hazardous12 open

Class C. HPD considers the condition an immediate danger: no heat in winter, no hot water, lead paint where a child lives, a broken lock on the front door. The owner has 24 hours to correct it.

  • Replace or repair the self-closing doors that is missing or defective latch set at building entrance door at public hall, 1st story

    Issued 29 Sept 2026Notice sent out 4 Oct 2026Fire and safety equipment§ 27-2005 +3

  • Replace or repair the self-closing doors that is missing or defective hinges in the entrance, 3rd story at south

    Issued 29 Sept 2026Notice sent out 4 Oct 2026Fire and safety equipment§ 27-2005 +3

  • Properly repair with similar material the broken or defective ceramic floor tile in the kitchen, 2nd story at north

    Issued 31 Jul 2026Notice sent out 6 Aug 2026Floors and stairs§ 27-2005

  • Properly repair or replace the broken or defective glass pane at lower sash l, 1st from north at east in the kitchen, 2nd story at north

    Issued 31 Jul 2026Notice sent out 6 Aug 2026§ 27-2005

  • Properly repair or replace the broken or defective heavy duty lockset at building entrance door

    Issued 31 Jul 2026Notice sent out 6 Aug 2026Doors and windows§ 27-2005

  • Abate the infestation consisting of roaches in the entire apartment, 2nd story at west

    Issued 30 Sept 2020Notice of issuance sent to tenant 4 Oct 2020Pests§ 27-2017.4

  • Abate the infestation consisting of roaches in the entire apartment, 1st story at west

    Issued 19 Aug 2019First no access to re- inspect violation 29 Feb 2020Pests§ 27-2017.4

  • Abate the infestation consisting of roaches in the entire apartment, 1st story

    Issued 8 Jul 2019First no access to re- inspect violation 29 Feb 2020Pests§ 27-2017.4

  • Correct the lead-based paint hazard - paint that tested positive for lead content and that is peeling or on a deteriorated subsurface - using work practices set forth in 28 rcny §11-06(b)(2) 1st door frame from north at east wall, 1st door frame from south at west wall in the 2nd room from east, 2nd story at north

    Issued 21 May 2014First no access to re- inspect violation 29 Feb 2020Lead paint§ 27-2056.6

  • Correct the lead-based paint hazard - paint that tested positive for lead content and that is peeling or on a deteriorated subsurface - using work practices set forth in 28 rcny §11-06(b)(2) 1st door from north at east wall, 1st door frame from north at east wall in the 5th room from east, 2nd story at north

    Issued 21 May 2014First no access to re- inspect violation 29 Feb 2020Lead paint§ 27-2056.6

Show all 12
  • Correct the lead-based paint hazard - paint that tested positive for lead content and that is peeling or on a deteriorated subsurface - using work practices set forth in 28 rcny §11-06(b)(2) 1st door frame from south at west wall in the 4th room from east, 2nd story at north

    Issued 21 May 2014First no access to re- inspect violation 29 Feb 2020Lead paint§ 27-2056.6

  • Correct the lead-based paint hazard - paint that tested positive for lead content and that is peeling or on a deteriorated subsurface - using work practices set forth in 28 rcny §11-06(b)(2) 1st closet from east at south wall door, 1st door frame from south at west wall, north wall, east wall, west wall, 1st window frame from north at east wall, 2nd window frame from north at east wall, 1st window frame from south at west wall in the kitchen, 2nd story at north

    Issued 21 May 2014First no access to re- inspect violation 29 Feb 2020Lead paint§ 27-2056.6

Hazardous10 open

Class B. A hazardous condition: a leak, mould, a defective floor. The owner has 30 days to correct it.

  • Repair the roof so that it will not leak at ceiling, west and north walls in the 2nd bathroom from north, 3rd story at south

    Issued 29 Sept 2026Notice sent out 4 Oct 2026Leaks and plumbing§ 27-2005

  • Repair the roof so that it will not leak at west wall in the 5th room from east at south, 3rd story at south

    Issued 29 Sept 2026Notice sent out 4 Oct 2026Leaks and plumbing§ 27-2005

  • Repair the broken or defective plastered surfaces and paint in a uniform color at ceiling, west and north walla in the 2nd bathroom from north, 3rd story at south

    Issued 29 Sept 2026Notice sent out 4 Oct 2026Walls and ceilings§ 27-2005

  • Repair the roof so that it will not leak at south wall in the 4th room from east, 3rd story at south

    Issued 29 Sept 2026Notice sent out 4 Oct 2026Leaks and plumbing§ 27-2005

  • Repair the broken or defective plastered surfaces and paint in a uniform color at south wall in the 4th room from east, 3rd story at south

    Issued 29 Sept 2026Notice sent out 4 Oct 2026Walls and ceilings§ 27-2005

  • Properly repair with similar material the broken or defective fire retardant material at ceiling, east, south, and west walls approx 10 sq ft. at public hall, 3rd story

    Issued 29 Sept 2026Notice sent out 4 Oct 2026Walls and ceilings§ 27-2005

  • Repair the roof so that it will not leak at ceiling at public hall, 3rd story

    Issued 29 Sept 2026Notice sent out 4 Oct 2026Leaks and plumbing§ 27-2005

  • Repair, replace or provide an approved and operational smoke detecting device, installed in accordance with department of buildings rules and regulations that is missing in the entire apartment, 2nd story at north

    Issued 31 Jul 2026Notice sent out 6 Aug 2026Fire and safety equipment§ 27-2045 +2

  • Repair, replace or provide an approved and operational carbon monoxide detecting device, installed in accordance with applicable law and rules that is missing in the entire apartment, 2nd story at north

    Issued 31 Jul 2026Notice sent out 6 Aug 2026Fire and safety equipment§ 27-2045 +3

  • Discontinue use of rooms for living, disconnect plumbing fixtures and properly seal pipe connections open space used for sleeping at basement apartment at basement

    Issued 4 Oct 2018First no access to re- inspect violation 29 Feb 2020Leaks and plumbing§ 27-2081

Non-hazardous1 open

Class A. The least serious band: chipped plaster, a missing cabinet, a peeling ceiling in a hallway. The owner has 90 days to correct it.

  • Paint with light colored paint to the satisfaction of this department at ceiling, east, west, and south walls at public hall, 3rd story

    Issued 29 Sept 2026Notice sent out 4 Oct 2026Walls and ceilings§ 27-2013

130 closed violations, plus 32 closed paperwork filings

Closed means HPD recorded the violation as corrected, or dismissed it. Both appear here, because the difference matters and only HPD’s own status line says which it was.

  • Properly repair with similar material the broken or defective porcelain finish at bath tub in the bathroom, 2nd story at east

    Issued 21 Aug 2019Violation dismissed 4 Jan 2024§ 27-2005

  • Dept. rules and regulations. remove the encumbrance obstructing egress from fire escapes consisting of protruding air conditioner at 2nd story window at rear south exterior wall

    Issued 4 Oct 2018Violation dismissed 4 Jan 2024Fire and safety equipment§ 27-2005 +1

  • Abate the nuisance consisting of wall mounted air conditioning units leaking throughout in the entire apartment, 1st story

    Issued 8 Jul 2019Violation dismissed 19 Nov 2023Leaks and plumbing§ 27-2005 +1

  • File plans and application and legalize the following alteration or restore to the legal condition existing prior to the making of said alteration floor pierced with stairs erected to cellar and creating illegal duplex apartment, 1st story

    Issued 4 Oct 2018Violation dismissed 19 Nov 2023Floors and stairs§ 300

  • Discontinue the rooming unit at cellar of illegal duplex apartment inconjunction with, 1st story

    Issued 4 Oct 2018Violation dismissed 19 Nov 2023§ 27-2077

  • Properly repair the source and abate the evidence of a water leak at east wall in the 2nd room from north, 2nd story at west

    Issued 30 Sept 2020Violation dismissed 3 Mar 2021Leaks and plumbing§ 27-2026

  • Repair the broken or defective plastered surfaces and paint in a uniform color at south wall in the 1st room from north, 2nd story at west

    Issued 30 Sept 2020Violation dismissed 3 Mar 2021Walls and ceilings§ 27-2005

  • Properly repair the source and abate the evidence of a water leak at south wall in the 1st room from north, 2nd story at west

    Issued 30 Sept 2020Violation dismissed 3 Mar 2021Leaks and plumbing§ 27-2026

  • Properly repair the source and abate the evidence of a water leak at east wall in the 5th room from north, 2nd story at west

    Issued 30 Sept 2020Violation dismissed 3 Mar 2021Leaks and plumbing§ 27-2026

  • Repair the broken or defective plastered surfaces and paint in a uniform color at east wall in the 5th room from north, 2nd story at west

    Issued 30 Sept 2020Violation dismissed 3 Mar 2021Walls and ceilings§ 27-2005

  • Repair the broken or defective plastered surfaces and paint in a uniform color at east wall in the 2nd room from north, 2nd story at west

    Issued 30 Sept 2020Violation dismissed 3 Mar 2021Walls and ceilings§ 27-2005

  • Cleanse to the satisfaction of this department the floor at public hall, 1st story

    Issued 30 Sept 2020Violation dismissed 21 Feb 2021Floors and stairs§ 27-2011

  • Repair or replace the smoke detector defective, 2nd story at west

    Issued 30 Sept 2020Violation dismissed 31 Jan 2021Fire and safety equipment§ 27-2045

  • Repair or replace the carbon monoxide detecting device(s). defective, 2nd story at west

    Issued 30 Sept 2020Violation dismissed 31 Jan 2021Fire and safety equipment§ 27-2046.1

  • Remove all encumbrances consisting of household items at public hall, 2nd story

    Issued 30 Sept 2020Violation dismissed 31 Jan 2021Fire and safety equipment§ 27-2005 +1

  • Arrange and make self-closing the doors in the entrance, 2nd story at west

    Issued 30 Sept 2020Violation dismissed 14 Jan 2021Fire and safety equipment§ 27-2044

  • Remove all encumbrances consisting of house hold items and bicyle at public hall, 2nd story

    Issued 29 Feb 2020Violation closed 6 Apr 2020Fire and safety equipment§ 27-2005 +1

  • Trace and repair the source and abate the nuisance consisting of mold... at east wall approx. 15 sq.ft lower level, 1st story

    Issued 4 Oct 2018Violation closed 29 Feb 2020Mold and damp§ 27-2005

  • File plans and application and legalize the following alteration or restore to the legal condition existing prior to the making of said alteration floor pierced at ist story and stairs installed leading to basement, 1st story at west

    Issued 26 Jun 2019Violation dismissed 26 Dec 2019Floors and stairs§ 300

  • Repair the broken or defective plastered surfaces and paint in a uniform color at ceiling in the 2nd bathroom from north at west, 1st story

    Issued 4 Oct 2018Violation closed 29 Aug 2019Walls and ceilings§ 27-2005

  • Provide adequate light of not less than 60 watts incandescent or equivalent illumination.. at public hall, 1st story

    Issued 6 Aug 2019Violation closed 25 Aug 2019Electrical§ 27-2039

  • Trace and repair the source and abate the visible mold condition... approxi. 16 sqft at north wall at cellar

    Issued 16 Jul 2019Violation closed 25 Aug 2019Mold and damp§ 27-2017.3

  • Repair the broken or defective plastered surfaces and paint in a uniform color north wall at cellar

    Issued 16 Jul 2019Violation closed 25 Aug 2019Walls and ceilings§ 27-2005

  • Repair or replace the smoke detector missing in the entire apartment, 1st story

    Issued 8 Jul 2019Violation closed 25 Aug 2019Fire and safety equipment§ 27-2045

  • Repair or replace the carbon monoxide detecting device(s). missing in the entire apartment, 1st story

    Issued 8 Jul 2019Violation closed 25 Aug 2019Fire and safety equipment§ 27-2046.1

  • Paint with light colored paint to the satisfaction of this department the ceilings in the entire apartment, 1st story at west

    Issued 26 Jun 2019Violation closed 25 Aug 2019Walls and ceilings§ 27-2013

  • Paint with light colored paint to the satisfaction of this department the walls in the entire apartment, 1st story at west

    Issued 26 Jun 2019Violation closed 25 Aug 2019Walls and ceilings§ 27-2013

  • Fire escape defective. adjust the dropladder so that it will slide easily in the guide rods at south fire escape at rear south yard

    Issued 4 Oct 2018Violation closed 25 Aug 2019Fire and safety equipment§ 27-2005

  • Dept. rules and regulations. remove the encumbrance obstructing egress from fire escapes consisting of flower pots and household items on 3rd story balcony at south fire escape at rear south yard

    Issued 4 Oct 2018Violation closed 25 Aug 2019Fire and safety equipment§ 27-2005 +1

  • Post notice, in form approved by the department, stating the name and location of the person designated by the owner to have key to buildings heating system... at public hall, 1st story

    Issued 1 Aug 2018Violation closed 25 Aug 2019Heat and hot water§ 27-2033

  • Post notice, in form approved by the department, stating the name and location of the person designated by the owner to have key to buildings heating system at, 1st story

    Issued 16 Nov 2017Violation closed 25 Aug 2019Heat and hot water§ 27-2033

  • Remove all encumbrances consisting of household items at public hall, 2nd story

    Issued 6 Nov 2017Violation closed 25 Aug 2019Fire and safety equipment§ 27-2005 +1

  • Post notice, in form approved by the department, stating the name and location of the person designated by the owner to have key to buildings heating system missing at wall at public hall, 1st story

    Issued 6 Nov 2017Violation closed 25 Aug 2019Heat and hot water§ 27-2033

  • Properly repair with similar material the broken or defective ceramic tiles at north wall at public hall, 1st story

    Issued 6 Nov 2017Violation closed 25 Aug 2019Walls and ceilings§ 27-2005

  • Arrange and make self-closing the doors to the apartment in the entrance, 2nd story at north

    Issued 23 Aug 2017Violation closed 25 Aug 2019Fire and safety equipment§ 27-2005 +1

  • Abate the nuisance consisting of a/c at the fire escape window in the kitchen, 2nd story at north

    Issued 23 Aug 2017Violation closed 25 Aug 2019Fire and safety equipment§ 27-2005 +1

  • Remove the illegal double cylinder key operated locking device at door to the apartment in the entrance, 2nd story at north

    Issued 23 Aug 2017Violation closed 25 Aug 2019Doors and windows§ 27-2005

  • Repair or replace the carbon monoxide detecting device(s). missing in the entire apartment, 2nd story at north

    Issued 20 Dec 2015Violation closed 25 Aug 2019Fire and safety equipment§ 27-2046.1

  • Abate the nuisance consisting of mice in the entire apartment, 2nd story at north

    Issued 20 Dec 2015Violation closed 25 Aug 2019Pests§ 27-2018

  • Abate the nuisance consisting of roaches in the entire apartment, 2nd story at north

    Issued 20 Dec 2015Violation closed 25 Aug 2019Pests§ 27-2018

  • Repair or replace the smoke detector missing in the entire apartment, 2nd story at north

    Issued 20 Dec 2015Violation closed 25 Aug 2019Fire and safety equipment§ 27-2045

  • Remove the illegal fastening (2) double cylinder locks installed at door in the entrance, 2nd story at north

    Issued 20 Dec 2015Violation closed 25 Aug 2019Doors and windows§ 27-2005 +1

  • Arrange and make self-closing the doors that is required in the entrance, 2nd story

    Issued 17 Dec 2014Violation closed 25 Aug 2019Fire and safety equipment§ 27-2005 +1

  • Paint with light colored paint to the satisfaction of this department the north wall, 1st door from south at west wall, 1st door from north at east wall in the 2nd room from east, 2nd story at north

    Issued 21 May 2014Violation closed 25 Aug 2019Doors and windows§ 27-2013

  • Trace and repair the source and abate the nuisance consisting of mold... at ceiling and walls ( apprx.20 sq.ft) in the bathroom, 2nd story at north

    Issued 21 May 2014Violation closed 25 Aug 2019Mold and damp§ 27-2005

  • Repair the flushing apparatus and maintain same so as to flush effectively the water closet.. in the bathroom, 2nd story at north

    Issued 21 May 2014Violation closed 25 Aug 2019§ 27-2026

  • Paint with light colored paint to the satisfaction of this department all peeling paint surfaces in the bathroom, 2nd story at north

    Issued 21 May 2014Violation closed 25 Aug 2019Walls and ceilings§ 27-2013

  • Repair or replace the carbon monoxide detecting device(s). inoperable, 2nd story at north

    Issued 21 May 2014Violation closed 25 Aug 2019Fire and safety equipment§ 27-2046.1

  • Repair the broken or defective plastered surfaces and paint in a uniform color the north wall in the 5th room from east, 2nd story at north

    Issued 21 May 2014Violation closed 25 Aug 2019Walls and ceilings§ 27-2005

  • Repair the broken or defective plastered surfaces and paint in a uniform color the east wall, south wall in the 4th room from east, 2nd story at north

    Issued 21 May 2014Violation closed 25 Aug 2019Walls and ceilings§ 27-2005

  • Repair or replace the smoke detector inoperable, 2nd story at north

    Issued 21 May 2014Violation closed 25 Aug 2019Fire and safety equipment§ 27-2045

  • Paint with light colored paint to the satisfaction of this department the 1st closet from east at south wall door frame, south wall in the kitchen, 2nd story at north

    Issued 21 May 2014Violation closed 25 Aug 2019Doors and windows§ 27-2013

  • Properly secure the loose sink at north wall in the bathroom, 2nd story at north

    Issued 21 May 2014Violation closed 25 Aug 2019Leaks and plumbing§ 27-2005

  • Abate the infestation consisting of roaches in the entire apartment, 1st story at west

    Issued 26 Jun 2019Violation closed 19 Aug 2019Pests§ 27-2017.4

  • Provide hot water at all hot water fixtures in the entire apartment, 1st story at south

    Issued 24 Jan 2019Violation closed 17 Feb 2019Heat and hot water§ 27-2031

  • Abate the nuisance consisting of hot water exceeding the maximum tmperature of 130 degrees at all hot water fixtures in the entire apartment, 1st story at south

    Issued 13 Jan 2019Violation closed 24 Jan 2019Heat and hot water§ 27-2005 +1

  • Properly repair the broken or defective electrical light fixtures at ceiling in the entire apartment, 1st story at south

    Issued 17 May 2018Violation closed 24 Jan 2019Electrical§ 27-2005

  • Correct the lead-based paint hazard - presumed lead paint that is peeling or is on a deteriorated subsurface - using exclusive interim controls. north wall in the kitchen, 3rd story

    Issued 21 May 2000Violation closed 4 Nov 2018Lead paint§ 27-2056.5

  • Correct the lead-based paint hazard - presumed lead paint that is peeling or on a deteriorated subsurface on wood trim, doors, or windows - using exclusive interim controls, which include a surface dust test in accordance with statute. east door frame in the bathroom, 3rd story

    Issued 21 May 2000Violation closed 4 Nov 2018Lead paint§ 27-2056.5

  • Correct the lead-based paint hazard - presumed lead paint that is peeling or is on a deteriorated subsurface - using exclusive interim controls. east riser in the bathroom, 3rd story

    Issued 21 May 2000Violation closed 4 Nov 2018Lead paint§ 27-2056.5

  • Correct the lead-based paint hazard - presumed lead paint that is peeling or on a deteriorated subsurface on wood trim, doors, or windows - using exclusive interim controls, which include a surface dust test in accordance with statute. east moldings in the foyer, 3rd story

    Issued 21 May 2000Violation closed 4 Nov 2018Lead paint§ 27-2056.5

  • Correct the lead-based paint hazard - presumed lead paint that is peeling or is on a deteriorated subsurface - using exclusive interim controls. east riser in the 2nd bedroom from west, 3rd story

    Issued 21 May 2000Violation closed 4 Nov 2018Lead paint§ 27-2056.5

  • Correct the lead-based paint hazard - presumed lead paint that is peeling or on a deteriorated subsurface on wood trim, doors, or windows - using exclusive interim controls, which include a surface dust test in accordance with statute. east door in the bathroom, 3rd story

    Issued 21 May 2000Violation closed 4 Nov 2018Lead paint§ 27-2056.5

  • Correct the lead-based paint hazard - presumed lead paint that is peeling or is on a deteriorated subsurface - using exclusive interim controls. north door frame in the kitchen, 3rd story

    Issued 21 May 2000Violation closed 4 Nov 2018Lead paint§ 27-2056.5

  • Correct the lead-based paint hazard - presumed lead paint that is peeling or is on a deteriorated subsurface - using exclusive interim controls. north closet door in the kitchen, 3rd story

    Issued 21 May 2000Violation closed 4 Nov 2018Lead paint§ 27-2056.5

  • Correct the lead-based paint hazard - presumed lead paint that is on a deteriorated subsurface that is unstable or unsound using exclusive interim controls. north closet ceiling in the kitchen, 3rd story

    Issued 21 May 2000Violation closed 4 Nov 2018Lead paint§ 27-2056.5

  • Replace with new the missing architrave at door at west at public hall, 2nd story

    Issued 6 Nov 2017Violation closed 1 Nov 2018Doors and windows§ 27-2005

  • Paint with light colored paint to the satisfaction of this department north and west walls at public hall, 3rd story

    Issued 6 Nov 2017Violation closed 1 Nov 2018Walls and ceilings§ 27-2013

  • Properly repair the broken or defective electrical switch at north wall in the 3rd room from east, 1st story at south

    Issued 17 May 2018Violation closed 1 Aug 2018Electrical§ 27-2005

  • Properly repair the broken or defective electrical switch at west wall in the 2nd room from north, 1st story

    Issued 7 May 2018Violation closed 1 Aug 2018Electrical§ 27-2005

  • Repair or replace the carbon monoxide detecting device(s). missing, 1st story

    Issued 7 May 2018Violation closed 1 Aug 2018Fire and safety equipment§ 27-2046.1

  • Repair or replace the smoke detector missing, 1st story

    Issued 7 May 2018Violation closed 1 Aug 2018Fire and safety equipment§ 27-2045

  • Properly repair the broken or defective electrical switch at east wall in the 3rd room from north, 1st story

    Issued 7 May 2018Violation closed 1 Aug 2018Electrical§ 27-2005

  • Repair or replace the smoke detector missing in the entire apartment, 3rd story at west

    Issued 16 Nov 2017Violation dismissed 15 Mar 2018Fire and safety equipment§ 27-2045

  • Provide an approved and operational carbon monoxide detecting device, installed in accordance with applicable law and rules. in the entire apartment, 3rd story at west

    Issued 16 Nov 2017Violation dismissed 15 Mar 2018Fire and safety equipment§ 27-2046.1

  • Arrange and make self-closing the doors... in the entrance, 3rd story at west

    Issued 16 Nov 2017Violation dismissed 15 Mar 2018Fire and safety equipment§ 27-2005 +1

  • Paint with light colored paint to the satisfaction of this department all peeling paint surfaces in the kitchen, the 1st room from east, the bathroom, 2nd story at north

    Issued 23 Aug 2017Violation dismissed 25 Feb 2018Walls and ceilings§ 27-2013

  • Arrange and make self-closing the doors.. in the entrance, 2nd story at south

    Issued 6 Nov 2017Violation closed 31 Jan 2018Fire and safety equipment§ 27-2005 +1

  • Repair or replace the carbon monoxide detecting device(s). missing in the entire apartment, 2nd story at south

    Issued 6 Nov 2017Violation closed 31 Jan 2018Fire and safety equipment§ 27-2046.1

  • Repair or replace the smoke detector missing in the entire apartment, 2nd story at south

    Issued 6 Nov 2017Violation closed 31 Jan 2018Fire and safety equipment§ 27-2045

  • Repair or replace the smoke detector missing in the entire apartment, 1st story at west

    Issued 16 Nov 2017Violation closed 28 Jan 2018Fire and safety equipment§ 27-2045

  • Repair or replace the carbon monoxide detecting device(s). missing in the entire apartment, 1st story at west

    Issued 16 Nov 2017Violation closed 28 Jan 2018Fire and safety equipment§ 27-2046.1

  • Replace with new the missing door lock at rear exit door, 1st story at west

    Issued 16 Nov 2017Violation closed 28 Jan 2018Doors and windows§ 27-2005

  • Arrange and make self-closing the doors... in the entrance, 1st story at west

    Issued 16 Nov 2017Violation closed 28 Jan 2018Fire and safety equipment§ 27-2005 +1

  • 2011, 2012 adm code remove the accumulation of refuse and/or rubbish and maintain in a clean condition the roof, consisting of bottles and building material

    Issued 16 Nov 2017Violation closed 28 Jan 2018Garbage and cleanliness§ 27-2010

  • Dept. rules and regulations. remove the encumbrance obstructing egress from fire escapes window gates and household items at 3rd story balcony at fire escape at east

    Issued 6 Nov 2017Violation closed 28 Jan 2018Fire and safety equipment§ 27-2005 +1

  • Remove all encumbrances consisting of construction debris at roof

    Issued 6 Nov 2017Violation closed 28 Jan 2018Fire and safety equipment§ 27-2005 +1

  • Fire escape defective. adjust the dropladder so that it will slide easily in the guide rods reset in the up position at fire escape, 1st story

    Issued 17 Dec 2014Violation closed 28 Jan 2018Fire and safety equipment§ 27-2005

  • 2011, 2012 adm code remove the accumulation of refuse and/or rubbish and maintain in a clean condition the debris, house hole items through out rear yard

    Issued 17 Dec 2014Violation closed 8 Nov 2017Garbage and cleanliness§ 27-2010

  • Dept. rules and regulations. remove the encumbrance obstructing egress from fire escapes house hold items all sty's at fire escape, 1st story

    Issued 17 Dec 2014Violation dismissed 8 Nov 2017Fire and safety equipment§ 27-2005 +1

  • Properly repair the broken or defective ceiling light fixture in the bathroom, 2nd story

    Issued 17 Dec 2014Violation closed 8 Nov 2017Walls and ceilings§ 27-2005

  • Provide ventilation in the bathroom, 2nd story

    Issued 17 Dec 2014Violation closed 8 Nov 2017§ 27-2005

  • Remove the illegal fastening key operated double cylinder lock at door at vestibule, 1st story

    Issued 17 Dec 2014Violation closed 8 Nov 2017Doors and windows§ 27-2005 +1

  • Remove the illegal fastening hasp and lock installed at vestibule door at public hall, 1st story

    Issued 20 Dec 2015Violation dismissed 25 Jan 2016Doors and windows§ 27-2005 +1

  • Install the missing or repair/replace the defective window guard(s) in accordance with the specifications of the new york city health code section 24 rcny chapter 12. wg to install = 2; wg to replace = 0; wg to repair = 1;, 2nd story at north

    Issued 21 May 2014Violation closed 17 Jul 2014Fire and safety equipment§ 27-2043.1

  • Properly repair the broken or defective mortise lock at doors in the entrance, 2nd story at west

    Issued 4 Feb 2014Violation closed 26 May 2014Doors and windows§ 27-2005

  • Properly repair with similar material the broken or defective wood floor in the kitchen, 2nd story at west

    Issued 4 Feb 2014Violation closed 26 May 2014Floors and stairs§ 27-2005

  • Properly repair with similar material the broken or defective wood floor in the 2nd room from east, 2nd story at west

    Issued 4 Feb 2014Violation closed 26 May 2014Floors and stairs§ 27-2005

  • Arrange and make self-closing the doors.. in the entrance, 2nd story at west

    Issued 4 Feb 2014Violation closed 26 May 2014Fire and safety equipment§ 27-2044

  • Replace the broken or defective washbasin in the bathroom, 2nd story at west

    Issued 4 Feb 2014Violation closed 26 May 2014§ 27-2026

Showing the 100 most recent of 130.

185 violations on record in total, 23 of them open. The count at the top of this page counts habitability violations only.

Complaints to the city

Public complaint

Complaints are reports made to the city. They are not confirmed findings. They come from HPD and from 311, and the same problem can appear more than once if more than one neighbour called.

26 complaints in three years, 22 of them in the last twelve months.

  • Leaks and plumbing5 / 7
  • Walls and ceilings5 / 5
  • Doors and windows4 / 4
  • Noise3 / 3
  • Floors and stairs2 / 2
  • Pests0 / 1
  • Entry, buzzer and mail1 / 1
  • Construction and illegal work1 / 1
  • Heat and hot water0 / 1
  • Mold and damp1 / 1

Last twelve months / last three years. The solid part of each bar is the last twelve months.

Court records

Court record

Housing Court cases

Cases the city’s housing department (HPD) brought against the owner, usually to force repairs or restore heat. A case is an allegation; where the court recorded an outcome, it is shown.

5 cases, all closed.

  • Comp Supplemental Cases

    Opened 22 Jul 2019

  • Tenant Action/Harassment

    Opened 7 Sept 2018

  • Tenant Action

    Opened 10 May 2018

  • Comprehensive

    Opened 24 Apr 2018

  • Tenant Action

    Opened 23 Jan 2014

Evictions

Residential evictions carried out by a city marshal since 2017. Most follow a case for unpaid rent, so a count here is not by itself a finding about the building or the landlord. We show how many, never which apartment.

No marshal evictions recorded at this building since 2017.

Filings

Public filing

Building permits

No DOB permits filed for this building in the last five years.

Annual bedbug report

Every multiple dwelling in New York must file this once a year. A report of zero infested units is good news. No report is not: failing to file is itself a violation.

  • 2025No infested units reported (2024 report)
Show 6 earlier reports
  • 2024No infested units reported (2023 report)
  • 2024No infested units reported (2022 report)
  • 2023No infested units reported (2022 report)
  • 2022No infested units reported (2021 report)
  • 2021No infested units reported (2020 report)
  • 2021No infested units reported (2019 report)

Ownership and management

Public filing

Associations come from registration records and may be incomplete. Owners register with HPD once a year, so a change of hands can go unrecorded for a full cycle.

  • Registered managing agent

    DEODAT LOWTAN

    Public records list DEODAT LOWTAN as the registered managing agent for this address as of 13 Jul 2025. Source: HPD registration.

    Other buildings listed under this agent (24 in the records we hold, 10 shown)

    Show 7 more

    No combined rating for this agent yet. A portfolio rating needs at least 5 verified reviews across 2 or more buildings; currently 0.

  • Owner of record

    PEOPLE HOME IMPROVEMENT LLC

    Public records list PEOPLE HOME IMPROVEMENT LLC as the owner of record for this address as of 13 Jul 2025. Source: HPD registration.

Wrong company, wrong date, or a change that is not reflected here? Report a correction.

What to ask at the viewing

Drawn from this building’s record above. They are questions, not conclusions: the point is to find out, in the twenty minutes you get inside, what the public record cannot tell you.

  1. The city currently has 12 open immediately-hazardous violations on this building. Ask which apartments they concern, how many are in the one you would be renting, and when HPD re-inspects.
  2. There was 1 mould complaint here in the last twelve months. Ask to look behind furniture and under sinks, and ask what was done the last time; a repaint is not a repair.
  3. The owner has filed a bedbug report for this building (most recently for the year ending 2025). Ask when the building was last treated, how often an exterminator comes, and whether treatment covers the whole line of apartments or only the one that complained.
  4. This building dates from 1931 and has 4 open lead-paint violations on record. If a child under six will live here, ask what testing and remediation has been done and ask for it in writing.
  5. Ask what the deposit is, exactly what can be deducted from it, and how and when it comes back.
  6. Ask who to call when something breaks, what happens after hours and at weekends, and how long a repair normally takes.

Ask for anything that matters in writing; an email after the viewing is enough. We are not your lawyer and this is not legal advice.

Questions about this building

BBL 3032360013 · Block 3236, Lot 13 · Building class C2