ByTenantsByTenants home

72-14 69 Place, Ridgewood, NY 11385

Built 1931 · 3-story walk-up · 6 apartments

16 immediately hazardous violations open. 59 open in all. On the state's rent-stabilization list for 2024.

Tenant reviews
None yetLived here? Reviews open soon.
Open violations
5916 · 33 · 10
Public record
Updated yesterdayFrom the city’s own data (, 311, the courts), refreshed nightly.

Violations issued each year

Violations issued each year
YearHazardousNon-hazardous
2022110
2023266
2024243
202501
2026 so far00

Plus 149 violations from 2009 to 2021. Counted when issued, whether open or fixed since. Paperwork left out.

See every violation
Found most often since 2022
  • Walls and ceilings 12
  • Fire and safety equipment 11
  • Floors and stairs 9
Open per apartment
9.8 (59 open across 6 apartments)
Inspector last found a problem
14 Jan 2025 (visits that find nothing are not published)
What do these labels mean?
Tenant-reported
A resident's firsthand account of living here, moderated before it publishes, and labelled with whether we verified they lived there.
Official violation
A city inspector visited and recorded a code violation. HPD's own words, and its own hazard class.
Public complaint
A complaint somebody made to a city system, through HPD or 311. A report, not a finding: nobody has necessarily inspected it.
Public filing
A permit, a registration, a bedbug report: a document the owner filed with the city because the law requires it.
Court record
A Housing Court case HPD brought against the owner, or an eviction a city marshal carried out. A court's record: a case is an allegation until it ends in a finding.
Insufficient data
Not enough current information here to infer a pattern either way.

Tenant reviews

Tenant-reported

No tenant reviews yet. Lived here? Be the first.

Nothing above this section came from a tenant. It is all filed by the city, which means it only holds what somebody reported and an inspector wrote down, not what it is actually like to live here.

Not open yet. Reviews open when this neighbourhood does.

Heat season

No heat or hot-water complaints or violations were recorded here last winter (2025–26). That is the city's record: it only holds what somebody reported.

WinterDaysComplaintsViolations
2025–26000

The rules, 1 October to 31 May: from 6am to 10pm, when it is below 55°F outside, the apartment must be at least 68°F; overnight it must be at least 62°F whatever the weather. Hot water must be at least 120°F all year. A tenant without heat can report it to 311.

Rent stabilization

Public filing

The owner registered at least one rent-stabilized apartment here with the state for 2024. The list does not say which apartments, or how many.

Source: Rent Guidelines Board building list, from the state's 2024 registrations. To know about one apartment, a tenant can ask the state for its rent history through Ask HCR.

City violations

Official violation

Immediately hazardous16 open

Class C. HPD considers the condition an immediate danger: no heat in winter, no hot water, lead paint where a child lives, a broken lock on the front door. The owner has 24 hours to correct it.

  • Repair the roof so that it will not leak at bulkhead ceiling

    Issued 19 Dec 2024Notice certified late 9 Jan 2025Leaks and plumbing§ 27-2005

  • Properly repair with similar material the broken or defective fire rated material at bulkhead ceiling

    Issued 19 Dec 2024Notice certified late 9 Jan 2025Walls and ceilings§ 27-2005

  • Replace with new the missing wire mesh under skylight at bulkhead

    Issued 19 Dec 2024Notice certified late 9 Jan 2025Roof and outside the building§ 27-2005

  • ×2Abate the infestation consisting of roaches in the entire apartment, 2nd story at south

    2 issued 12 Sept 2020 to 4 Dec 2024First no access to re- inspect violationPests§ 27-2017.4

  • Provide a safe and adequate supply of electric service to the fixtures at ceiling in the bathroom, 2nd story at south

    Issued 22 Dec 2023First no access to re- inspect violation 16 Dec 2024Electrical§ 27-2037

  • Properly repair the source and abate the evidence of a water leak at ceiling in the bathroom, 2nd story at south

    Issued 22 Dec 2023First no access to re- inspect violation 16 Dec 2024Leaks and plumbing§ 27-2026

  • Repair the broken or defective plastered surfaces and paint in a uniform color at ceiling in the bathroom, 2nd story at south

    Issued 22 Dec 2023First no access to re- inspect violation 16 Dec 2024Walls and ceilings§ 27-2005

  • Properly repair or replace the broken or defective room door in the 1st room from north at east, 3rd story at south

    Issued 22 Dec 2023First no access to re- inspect violation 16 Dec 2024Doors and windows§ 27-2005

  • Properly repair or replace the broken or defective apartment door in the entrance, 3rd story at south

    Issued 22 Dec 2023First no access to re- inspect violation 16 Dec 2024Doors and windows§ 27-2005

  • Abate the infestation consisting of mice in the entire apartment, 2nd story at south

    Issued 18 Oct 2023First no access to re- inspect violation 16 Dec 2024Pests§ 27-2017.4

Show all 16
  • Replace or repair the self-closing doors that is missing or defective defective hinges in the entrance, 2nd story at west

    Issued 21 Sept 2023First no access to re- inspect violation 16 Dec 2024Fire and safety equipment§ 27-2005 +3

  • Provide ready access to buildings heating system door locked at basement, 1st story

    Issued 5 Aug 2022Not complied with 16 Dec 2024Heat and hot water§ 27-2033

  • Replace with new the broken or defective marble treads 1,2nd and 3rd up from bottom in the vestibule at public hall stairs, 1st story

    Issued 19 Aug 2021Not complied with 16 Dec 2024Floors and stairs§ 27-2005

  • Abate the nuisance consisting of privicy lock installed at door leading to fire escape window in the 1st room from north at east, 3rd story at south

    Issued 19 Aug 2021First no access to re- inspect violation 16 Dec 2024Fire and safety equipment§ 27-2005 +1

  • Replace with new the broken or defective marble treads at 1st and 2nd treads up from bottom,at vestibule leading to 1stry public hall, 1st story

    Issued 12 Jan 2021Not complied with 16 Dec 2024§ 27-2005

Hazardous33 open

Class B. A hazardous condition: a leak, mould, a defective floor. The owner has 30 days to correct it.

  • Refit door at building front entrance at public hall, 1st story

    Issued 16 Dec 2024Notice sent out 17 Dec 2024Doors and windows§ 27-2005

  • Remove all encumbrances consisting of household items at public hall, 1st story

    Issued 4 Dec 2024Not complied with 16 Dec 2024Fire and safety equipment§ 27-2005 +1

  • Properly repair with similar material the broken or defective floor tiles in the bathroom, 1st story at west

    Issued 5 Jun 2024First no access to re- inspect violation 16 Dec 2024Floors and stairs§ 27-2005

  • Abate the infestation consisting of bedbugs in the entire apartment, 1st story at west

    Issued 5 Jun 2024First no access to re- inspect violation 16 Dec 2024Pests§ 27-2017.4

  • Properly repair with similar material the broken or defective soft and rotten wood floor in the foyer, 1st story at west

    Issued 5 Jun 2024First no access to re- inspect violation 16 Dec 2024Floors and stairs§ 27-2005

  • Properly repair with similar material the broken or defective rotten wood floor in the 1st room from north at west, 1st story at west

    Issued 5 Jun 2024First no access to re- inspect violation 16 Dec 2024Floors and stairs§ 27-2005

  • Properly repair with similar material the broken or defective rotten wood floor in the 1st room from north at east, 1st story at west

    Issued 5 Jun 2024First no access to re- inspect violation 16 Dec 2024Floors and stairs§ 27-2005

  • Properly repair with similar material the broken or defective rotten wood floor in the kitchen, 1st story at west

    Issued 5 Jun 2024First no access to re- inspect violation 16 Dec 2024Floors and stairs§ 27-2005

  • Properly repair with similar material the broken or defective rotten wood floor in the private hallway, 1st story at west

    Issued 5 Jun 2024First no access to re- inspect violation 16 Dec 2024Floors and stairs§ 27-2005

  • Trace and repair the source and abate the visible mold condition... at ceiling in the bathroom, 2nd story at south

    Issued 22 Dec 2023First no access to re- inspect violation 16 Dec 2024Mold and damp§ 27-2017.3

Show all 33
  • Properly repair or replace the broken or defective 1st,2nd and 3rd marble threads from bottom at vestibule stairs at 1st floor public hall at public hall, 1st story

    Issued 18 Oct 2023Not complied with 16 Dec 2024Floors and stairs§ 27-2005

  • Repair or replace the carbon monoxide detecting device(s). defective in the entire apartment, 2nd story at south

    Issued 18 Oct 2023First no access to re- inspect violation 16 Dec 2024Fire and safety equipment§ 27-2046.1

  • Repair or replace the smoke detector defective in the entire apartment, 2nd story at south

    Issued 18 Oct 2023First no access to re- inspect violation 16 Dec 2024Fire and safety equipment§ 27-2045

  • Trace and repair the source and abate the visible mold condition... approx 8 sq ft at the ceiling in the bathroom, 2nd story at west original violation 16243306 issued 21-sep-23 has been upgraded to class b per administrative code §27-2017.3a(3)(a) or (b).

    Issued 21 Sept 2023First no access to re- inspect violation 16 Dec 2024Mold and damp§ 27-2017.3

  • Provide a safe and adequate supply of electric service to the fixtures light at the ceiling in the bathroom, 2nd story at west

    Issued 21 Sept 2023First no access to re- inspect violation 16 Dec 2024Electrical§ 27-2037

  • Properly repair the source and abate the evidence of a water leak ceiling in the bathroom, 2nd story at south

    Issued 5 Jan 2022First no access to re- inspect violation 16 Dec 2024Leaks and plumbing§ 27-2026

  • Provide a safe and adequate supply of electric service to the fixtures ceiling light fixture and electrical outlet at west wall in the bathroom, 2nd story at south

    Issued 5 Jan 2022First no access to re- inspect violation 16 Dec 2024Electrical§ 27-2037

  • Repair the broken or defective plastered surfaces and paint in a uniform color all walls in the bathroom, 2nd story at south

    Issued 5 Jan 2022First no access to re- inspect violation 16 Dec 2024Walls and ceilings§ 27-2005

  • Replace with new the broken or defective door handle in the 2nd room from north at east, 3rd story at south

    Issued 19 Aug 2021First no access to re- inspect violation 16 Dec 2024Doors and windows§ 27-2005

  • Properly repair with similar material the broken or defective wood door molding in the 1st room from north at east, 3rd story at south

    Issued 19 Aug 2021First no access to re- inspect violation 16 Dec 2024Doors and windows§ 27-2005

  • Properly repair the broken or defective mortise lock in the entrance, 3rd story at south

    Issued 19 Aug 2021First no access to re- inspect violation 16 Dec 2024§ 27-2005

  • Properly repair with similar material the broken or defective wooden tiles at floor in the bathroom, 1st story at west

    Issued 9 Jun 2021First no access to re- inspect violation 16 Dec 2024Floors and stairs§ 27-2005

  • Replace with new the broken or defective ceramic tiles 1st and 2nd trades at vetibule to building entry stairs, 1st story

    Issued 3 Mar 2021Not complied with 16 Dec 2024Floors and stairs§ 27-2005

  • Repair the broken or defective plastered surfaces and paint in a uniform color west wall in the foyer, 2nd story at south

    Issued 12 Sept 2020First no access to re- inspect violation 16 Dec 2024Walls and ceilings§ 27-2005

  • Repair the broken or defective plastered surfaces and paint in a uniform color ceiling in the bathroom, 2nd story at south

    Issued 12 Sept 2020First no access to re- inspect violation 16 Dec 2024Walls and ceilings§ 27-2005

  • Repair or replace the smoke detector defective, 2nd story at south

    Issued 12 Sept 2020First no access to re- inspect violation 16 Dec 2024Fire and safety equipment§ 27-2045

  • Repair or replace the carbon monoxide detecting device(s). defective, 2nd story at south

    Issued 12 Sept 2020First no access to re- inspect violation 16 Dec 2024Fire and safety equipment§ 27-2046.1

  • Properly repair the source and abate the evidence of a water leak west wall in the foyer, 2nd story at south

    Issued 12 Sept 2020First no access to re- inspect violation 16 Dec 2024Leaks and plumbing§ 27-2026

  • Properly repair with similar material the broken or defective fire retardant plaster at ceiling & all walls throughout at cellar

    Issued 27 Feb 2020First no access to re- inspect violation 16 Dec 2024Walls and ceilings§ 27-2005

  • Properly secure the loose 3rd. marble tread from bottom up at vestibule hall stair, 1st story

    Issued 27 Feb 2020Not complied with 16 Dec 2024Floors and stairs§ 27-2005

  • Repair the broken or defective connection wasteline at wash basin in the bathroom, 2nd story at north

    Issued 20 Dec 2019First no access to re- inspect violation 16 Dec 2024§ 27-2026

  • Repair the leaky and/or defective water supply pipe at wash basin in the bathroom, 2nd story at west

    Issued 23 Oct 2019First no access to re- inspect violation 16 Dec 2024Leaks and plumbing§ 27-2026

  • Remove all obstructions and repair all defects in bathtub drain in the bathroom, 2nd story at west

    Issued 23 Oct 2019First no access to re- inspect violation 16 Dec 2024Leaks and plumbing§ 27-2026

Non-hazardous10 open

Class A. The least serious band: chipped plaster, a missing cabinet, a peeling ceiling in a hallway. The owner has 90 days to correct it.

  • 187, 231 m/d law and department rules and regulations. provide a shoe properly secured to bottom of string of dropladder at front of building

    Issued 14 Jan 2025Notice sent out 15 Jan 2025§ 53

  • Paint with light colored paint to the satisfaction of this department at bulkhead ceiling

    Issued 19 Dec 2024Invalid certification 9 Jan 2025Walls and ceilings§ 27-2013

  • Paint with light colored paint to the satisfaction of this department at bulkhead ceiling

    Issued 18 Nov 2024Not complied with 16 Dec 2024Walls and ceilings§ 27-2013

  • Replace with new the defective flush pipe of water closet in the bathroom, 1st story at west

    Issued 5 Jun 2024First no access to re- inspect violation 16 Dec 2024§ 27-2026

  • Repair the broken or defective plastered surfaces and paint in a uniform color the west wall in the foyer, 2nd story at south

    Issued 18 Oct 2023First no access to re- inspect violation 16 Dec 2024Walls and ceilings§ 27-2005

  • Properly repair the source and abate the evidence of a water leak at west wall in the foyer, 2nd story at south

    Issued 18 Oct 2023First no access to re- inspect violation 16 Dec 2024Leaks and plumbing§ 27-2026

  • Repair the broken or defective plastered surfaces and paint in a uniform color the ceiling in the 3rd room from north at west, 2nd story at south

    Issued 18 Oct 2023First no access to re- inspect violation 16 Dec 2024Walls and ceilings§ 27-2005

  • Properly repair the source and abate the evidence of a water leak at ceiling in the 3rd room from north at west, 2nd story at south

    Issued 18 Oct 2023First no access to re- inspect violation 16 Dec 2024Leaks and plumbing§ 27-2026

  • Repair the broken or defective plastered surfaces and paint in a uniform color at south and west wall in the bathroom, 2nd story at south

    Issued 18 Oct 2023First no access to re- inspect violation 16 Dec 2024Walls and ceilings§ 27-2005

  • Repair the broken or defective connection waste line under basin/sink in the bathroom, 2nd story at north

    Issued 31 Aug 2019First no access to re- inspect violation 16 Dec 2024Leaks and plumbing§ 27-2026

Orders and notices1 open

An order issued against the building as a whole rather than a condition in one apartment: a vacate order, or selection for HPD's Alternative Enforcement Program for buildings with persistent violations.

  • The premises has been selected to participate in the alternative enforcement program which may result in building-wide inspections, fees, and extensive repair work to correct violations and underlying conditions. charges for repair work done pursuant to this order, if not paid, will become liens on the property

    Issued 31 Jan 2022Info notice sent out 1 Feb 2022§ 27-2153

Paperwork and notices7 open

The owner failed to file something the city requires, most often the annual property registration or the annual bedbug report. Real violations, and they say something about an owner, but not a condition anyone is living in. Kept out of the count at the top of this page for that reason.

  • ×2File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.

    2 issued 11 Jun 2025 to 6 May 2026Notice sent outPaperwork and notices

  • Owner failed to file a valid registration statement with the department as required by adm code §27-2097 and is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.

    Issued 21 Nov 2025Info notice sent out 20 Nov 2025Paperwork and notices§ 27-2107

  • ×2Owner failed to file a valid registration statement with the department as required by adm code §27-2097 and is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.

    2 issued 16 Nov 2022 to 2 Dec 2024Not complied withPaperwork and notices§ 27-2107

  • ×2File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.

    2 issued 3 Mar 2022 to 15 Apr 2024First no access to re- inspect violationPaperwork and notices

162 closed violations, plus 10 closed paperwork filings

Closed means HPD recorded the violation as corrected, or dismissed it. Both appear here, because the difference matters and only HPD’s own status line says which it was.

  • Properly repair with similar material the broken or defective fire reated material at bulkhead ceiling

    Issued 18 Nov 2024Violation closed 25 Dec 2025Walls and ceilings§ 27-2005

  • Repair the roof so that it will not leak over ceiling at public hall stairs, 3rd story, section ''bulkhead''

    Issued 16 Dec 2024Violation closed 9 Jul 2025Leaks and plumbing§ 27-2005

  • Replace with new the missing wire mesh under skylight at bulkhead

    Issued 18 Nov 2024Violation closed 4 May 2025Roof and outside the building§ 27-2005

  • Properly repair with similar material the broken or defective 1st, 2nd, and 3rd marble steps from bottom up, 1st story

    Issued 8 Aug 2024Violation closed 4 May 2025Floors and stairs§ 27-2005

  • Properly repair with similar material the broken or defective marble tread 1st,2nd and 3rd upper from bottom at vestibule at public hall stairs, 1st story

    Issued 5 Aug 2024Violation closed 4 May 2025Floors and stairs§ 27-2005

  • Properly repair with similar material the broken or defective broken 1st and 2nd marble treads from bottom at vestibule to 1st story public hall, 1st story

    Issued 1 Nov 2023Violation closed 4 May 2025§ 27-2005

  • Properly repair or replace the broken or defective lock set at front door enntrance at front areaway, 1st story

    Issued 4 Dec 2024Violation closed 16 Dec 2024Doors and windows§ 27-2005

  • Properly repair or replace the broken or defective lock at building entrance door at public hall, 1st story

    Issued 18 Nov 2024Violation closed 16 Dec 2024Doors and windows§ 27-2005

  • Properly repair or replace the broken or defective building entrance door lock at public hall, 1st story

    Issued 8 Aug 2024Violation closed 16 Dec 2024Doors and windows§ 27-2005

  • ×2Provide hot water at all hot water fixtures in the entire apartment, 3rd story at south

    2 issued 5 Aug 2022 to 22 Dec 2023Violation closedHeat and hot water§ 27-2031

  • Properly repair or replace the broken or defective lockset at building entrance door, 1st story

    Issued 1 Nov 2023Violation closed 16 Dec 2024Doors and windows§ 27-2005

  • Abate the infestation consisting of roaches in the entire apartment, 2nd story at south

    Issued 18 Oct 2023Violation dismissed 16 Dec 2024Pests§ 27-2017.4

  • Provide a safe and adequate supply of electric service to the fixtures at ceiling in the bathroom, 2nd story at south

    Issued 18 Oct 2023Violation dismissed 16 Dec 2024Electrical§ 27-2037

  • Repair the broken or defective plastered surfaces and paint in a uniform color unkeyed sheetrock approx 10 square feet at ceiling in the bathroom, 2nd story at south

    Issued 18 Oct 2023Violation dismissed 16 Dec 2024Walls and ceilings§ 27-2005

  • Properly repair the source and abate the evidence of a water leak at ceiling in the bathroom, 2nd story at south

    Issued 18 Oct 2023Violation dismissed 16 Dec 2024Leaks and plumbing§ 27-2026

  • Repair the broken or defective plastered surfaces and paint in a uniform color at the ceiling in the bathroom, 2nd story at west

    Issued 21 Sept 2023Violation dismissed 16 Dec 2024Walls and ceilings§ 27-2005

  • Repair or replace the smoke detector defective in the entire apartment, 2nd story at west

    Issued 21 Sept 2023Violation dismissed 16 Dec 2024Fire and safety equipment§ 27-2045

  • Repair or replace the carbon monoxide detecting device(s). defective in the entire apartment, 2nd story at west

    Issued 21 Sept 2023Violation dismissed 16 Dec 2024Fire and safety equipment§ 27-2046.1

  • Properly repair the source and abate the evidence of a water leak at the ceiling in the bathroom, 2nd story at west

    Issued 21 Sept 2023Violation dismissed 16 Dec 2024Leaks and plumbing§ 27-2026

  • Remove all encumbrances consisting of household items at public hall, 3rd story

    Issued 16 Aug 2023Violation closed 16 Dec 2024Fire and safety equipment§ 27-2005 +1

  • Properly repair the broken or defective building entrance door lock, 1st story

    Issued 19 Jan 2022Violation closed 16 Dec 2024Doors and windows§ 27-2005

  • And dept. rules and regulations. scrape and remove rust scales and paint with 2 coats of paint fire escape at building front

    Issued 24 Aug 2021Violation closed 16 Dec 2024Fire and safety equipment§ 27-2014

  • Replace or repair the self-closing doors that is missing or defective vestibule for to 1 story public hall

    Issued 24 Aug 2021Violation closed 16 Dec 2024Fire and safety equipment§ 27-2005 +2

  • Replace or repair the self-closing doors that is missing or defective vestibule door at public hall, 1st story

    Issued 19 Aug 2021Violation closed 16 Dec 2024Fire and safety equipment§ 27-2005 +2

  • And dept. rules and regulations. scrape and remove rust scales and paint with 2 coats of paint all stories front at fire escape

    Issued 18 Aug 2021Violation dismissed 16 Dec 2024Fire and safety equipment§ 27-2014

  • And dept. rules and regulations. scrape and remove rust scales and paint with 2 coats of paint all componets at 1st and 2nd story at building front at fire escape

    Issued 6 Aug 2021Violation dismissed 16 Dec 2024Fire and safety equipment§ 27-2014

  • And dept. rules and regulations. scrape and remove rust scales and paint with 2 coats of paint front all stories at fire escape

    Issued 27 Feb 2020Violation dismissed 16 Dec 2024Fire and safety equipment§ 27-2014

  • Repair the broken or defective connection at waste line under wash basin in the bathroom, 2nd story at west

    Issued 23 Oct 2019Violation dismissed 16 Dec 2024Leaks and plumbing§ 27-2026

  • And dept. rules and regulations. scrape and remove rust scales and paint with 2 coats of paint fire escape at all stories building front at fire escape

    Issued 23 Oct 2019Violation dismissed 16 Dec 2024Fire and safety equipment§ 27-2014

  • And dept. rules and regulations. scrape and remove rust scales and paint with 2 coats of paint at all stories building front

    Issued 3 Jun 2019Violation closed 16 Dec 2024Walls and ceilings§ 27-2014

  • Replace or repair the self-closing doors that is missing or defective hinges at public hall, 1st story

    Issued 18 Nov 2024Violation closed 15 Dec 2024Fire and safety equipment§ 27-2005 +3

  • Replace or repair the self-closing doors that is missing or defective vestibule hinges, 1st story

    Issued 8 Aug 2024Violation closed 15 Dec 2024Fire and safety equipment§ 27-2005 +3

  • Provide approved one-hour fire resistance rated self-closing door with key-operated dead bolt & latch set peephole & chain guard at main entrance... in the entrance, 1st story at west

    Issued 5 Jun 2024Violation closed 24 Aug 2024Fire and safety equipment§ 27-2005

  • Trace and repair the source and abate the visible mold condition... approx 8 sq ft at the ceiling in the bathroom, 2nd story at west

    Issued 21 Sept 2023Violation closed 19 Jan 2024Mold and damp§ 27-2017.3

  • Replace or repair the self-closing doors that is missing or defective repair the hinges at vestibule door to public hall, 1st story

    Issued 1 Nov 2023Violation closed 7 Jan 2024Fire and safety equipment§ 27-2005 +3

  • Provide hot water at all hot water fixtures in the entire apartment, 1st story at west

    Issued 2 Aug 2022Violation closed 10 Oct 2023Heat and hot water§ 27-2031

  • Provide a safe and adequate supply of electric service to the fixtures no electric supply at all stories at public hall

    Issued 2 Aug 2022Violation closed 25 Sept 2022Electrical§ 27-2037

  • Provide seal up opening shaft at south side of building leading to basement, 1st story

    Issued 28 Apr 2022Violation closed 25 Jul 2022§ 27-2005

  • Dept. rules and regulations. remove the encumbrance obstructing egress from fire escapes air conditioners protuding beyond window sill at 3rd stry balcony (building front) at fire escape

    Issued 19 Aug 2021Violation closed 14 Apr 2022Fire and safety equipment§ 27-2005 +1

  • Dept. rules and regulations. remove the encumbrance obstructing egress from fire escapes an air conditioner unit at 3rd sty east balcony at fire escape

    Issued 18 Aug 2021Violation closed 14 Apr 2022Fire and safety equipment§ 27-2005 +1

  • Provide seal up dumbwaiter door at the roof

    Issued 11 Feb 2022Violation closed 3 Apr 2022Roof and outside the building§ 27-2005

  • Repair the broken or defective plastered surfaces and paint in a uniform color ceiling in the bathroom, 2nd story at south

    Issued 5 Jan 2022Violation closed 14 Mar 2022Walls and ceilings§ 27-2005

  • Properly repair the broken or defective lock set at building entrance door

    Issued 24 Aug 2021Violation closed 3 Mar 2022Doors and windows§ 27-2005

  • Replace with new the broken or defective glass at upper window sash in the 2nd room from north at west, 3rd story at south

    Issued 19 Aug 2021Violation closed 13 Sept 2021Doors and windows§ 27-2005

  • The premises has been selected to participate in the alternative enforcement program which may result in building-wide inspections, fees, and extensive repair work to correct violations and underlying conditions. charges for repair work done pursuant to this order, if not paid, will become liens on the property

    Issued 1 Feb 2021Violation dismissed 1 Aug 2021§ 27-2153

  • Correct the lead-based paint hazard - presumed lead paint that is peeling or on a deteriorated subsurface using work practices set forth in 28 rcny §11-06(b)(2) north wall in the private hallway, 2nd story at south

    Issued 2 Jul 2019Violation closed 28 Jul 2021Lead paint§ 27-2056.6

  • Correct the lead-based paint hazard - presumed lead paint that is peeling or on a deteriorated subsurface using work practices set forth in 28 rcny §11-06(b)(2) 1st riser from west at north wall in the kitchen, 2nd story at south

    Issued 2 Jul 2019Violation closed 28 Jul 2021Lead paint§ 27-2056.6

  • Properly repair the source and abate the evidence of a water leak ceiling in the bathroom, 2nd story at south

    Issued 12 Sept 2020Violation closed 27 Jul 2021Leaks and plumbing§ 27-2026

  • Trace and repair the source and abate the visible mold condition... approximately 20 sq ft at ceiling, 2 sq ft at east wall, and 2 sq ft at west wall in the bathroom, 3rd story at south original violation 13916656 issued 29-nov-20 has been upgraded to class c per administrative code §27-2017.3a(5)(a) or (b).

    Issued 29 Nov 2020Violation closed 21 Jun 2021Mold and damp§ 27-2017.3

  • Properly secure the loose marble saddle in the bathroom, 3rd story at south

    Issued 29 Nov 2020Violation closed 15 Jun 2021§ 27-2005

  • Repair or replace the smoke detector missing, 3rd story at south

    Issued 29 Nov 2020Violation closed 15 Jun 2021Fire and safety equipment§ 27-2045

  • Repair or replace the carbon monoxide detecting device(s). missing, 3rd story at south

    Issued 29 Nov 2020Violation closed 15 Jun 2021Fire and safety equipment§ 27-2046.1

  • Dept. rules and regulations. remove the encumbrance obstructing egress from fire escapes at 3rd story balcony (building front )

    Issued 12 Sept 2020Violation closed 15 Jun 2021Fire and safety equipment§ 27-2005 +1

  • Remove all obstructions and repair all defects in wash/basin in the bathroom, 1st story

    Issued 27 Feb 2020Violation closed 15 Jun 2021§ 27-2026

  • Dept. rules and regulations. remove the encumbrance obstructing egress from fire escapes household items, 3rd and 2nd story balconies, east at fire escape

    Issued 21 Feb 2020Violation closed 15 Jun 2021Fire and safety equipment§ 27-2005 +1

  • Dept. rules and regulations. remove the encumbrance obstructing egress from fire escapes 3rd story balcony (building front at east )

    Issued 8 Dec 2019Violation closed 15 Jun 2021Fire and safety equipment§ 27-2005 +1

  • 2011, 2012 adm code remove the accumulation of refuse and/or rubbish and maintain in a clean condition the.. yard at north

    Issued 3 Jun 2019Violation closed 15 Jun 2021Garbage and cleanliness§ 27-2010

  • ×2Abate the infestation consisting of roaches in the entire apartment, 3rd story at north

    2 issued 29 Nov 2020 to 12 Jan 2021Violation will be reinspectedPests§ 27-2017.4

  • Abate the infestation consisting of roaches in the entire apartment, 3rd story at south

    Issued 29 Nov 2020Violation will be reinspected 13 Jun 2021Pests§ 27-2017.4

  • ×2Abate the infestation consisting of roaches in the entire apartment, 2nd story at north

    2 issued 31 Aug 2019 to 20 Dec 2019Violation will be reinspectedPests§ 27-2017.4

  • Abate the nuisance consisting of vermin bedbugs in the entire apartment, 1st story

    Issued 19 Jul 2009Violation will be reinspected 13 Jun 2021Pests§ 27-2018

  • Abate the nuisance consisting of vermin bedbugs throughout in the entire apartment, 1st story

    Issued 14 Jul 2009Violation will be reinspected 13 Jun 2021Pests§ 27-2018

  • Dept. rules and regulations. remove the encumbrance obstructing egress from fire escapes all house hold items at front of building, 3rd story

    Issued 25 Mar 2021Violation closed 8 Jun 2021Fire and safety equipment§ 27-2005 +1

  • Repair or replace the carbon monoxide detecting device(s). missing, 1st story at west

    Issued 31 Dec 2019Violation closed 8 Jun 2021Fire and safety equipment§ 27-2046.1

  • File plans and application and legalize the following alteration or restore to the legal condition existing prior to the making of said alteration acoustical drop ceiling in the kitchen, 1st story at west

    Issued 31 Dec 2019Violation closed 8 Jun 2021Walls and ceilings§ 300

  • File plans and application and legalize the following alteration or restore to the legal condition existing prior to the making of said alteration acoustical drop ceiling in the private hallway, 1st story at west

    Issued 31 Dec 2019Violation closed 8 Jun 2021Walls and ceilings§ 300

  • Repair or replace the smoke detector missing, 1st story at west

    Issued 31 Dec 2019Violation closed 8 Jun 2021Fire and safety equipment§ 27-2045

  • Repair or replace the carbon monoxide detecting device(s). missing, 2nd story at north

    Issued 20 Dec 2019Violation closed 8 Jun 2021Fire and safety equipment§ 27-2046.1

  • Repair or replace the smoke detector missing, 2nd story at north

    Issued 20 Dec 2019Violation closed 8 Jun 2021Fire and safety equipment§ 27-2045

  • File plans and application and legalize the following alteration or restore to the legal condition existing prior to the making of said alteration acoustic tiles suspended ceiling in the bathroom, 1st story at west

    Issued 23 Oct 2019Violation closed 8 Jun 2021Walls and ceilings§ 300

  • File plans and application and legalize the following alteration or restore to the legal condition existing prior to the making of said alteration acoustic tiles suspended ceiling in the foyer, 1st story at west

    Issued 23 Oct 2019Violation closed 8 Jun 2021Walls and ceilings§ 300

  • File plans and application and legalize the following alteration or restore to the legal condition existing prior to the making of said alteration acoustic tiles suspended ceiling in the private hallway, 1st story at west

    Issued 23 Oct 2019Violation closed 8 Jun 2021Walls and ceilings§ 300

  • File plans and application and legalize the following alteration or restore to the legal condition existing prior to the making of said alteration acoustic tiles suspended ceiling in the kitchen, 1st story at west

    Issued 23 Oct 2019Violation closed 8 Jun 2021Walls and ceilings§ 300

  • Repair or replace the smoke detector inoperable, 2nd story at north

    Issued 31 Aug 2019Violation closed 8 Jun 2021Fire and safety equipment§ 27-2045

  • Repair or replace the carbon monoxide detecting device(s). inoperable, 2nd story at north

    Issued 31 Aug 2019Violation closed 8 Jun 2021Fire and safety equipment§ 27-2046.1

  • Remove disused plumbing fixtures and properly seal pipe connections water closet at cellar front

    Issued 2 Jul 2019Violation closed 8 Jun 2021Leaks and plumbing§ 27-2026

  • Trace and repair the source and abate the visible mold condition... approximately 20 sq ft at ceiling, 2 sq ft at east wall, and 2 sq ft at west wall in the bathroom, 3rd story at south

    Issued 29 Nov 2020Violation closed 7 Jun 2021Mold and damp§ 27-2017.3

  • Properly repair the broken or defective mortise door lock at public hall, 1st story

    Issued 3 Mar 2021Violation closed 6 Jun 2021Doors and windows§ 27-2005

  • Provide ready access to buildings heating system door locked at 1stry public hall

    Issued 12 Jan 2021Violation closed 6 Jun 2021Heat and hot water§ 27-2033

  • Repair or replace the carbon monoxide detecting device(s). missing, 3rd story at north

    Issued 12 Jan 2021Violation closed 6 Jun 2021Fire and safety equipment§ 27-2046.1

  • Repair or replace the smoke detector missing, 3rd story at north

    Issued 12 Jan 2021Violation closed 6 Jun 2021Fire and safety equipment§ 27-2045

  • Provide an adequate supply of heat for the apartment in the entire apartment, 3rd story at south

    Issued 29 Nov 2020Violation closed 6 Jun 2021Heat and hot water§ 27-2029

  • Post notice, in form approved by the department, stating the name and location of the person designated by the owner to have key to buildings heating system missing at public hall, 1st story

    Issued 29 Nov 2020Violation closed 6 Jun 2021Heat and hot water§ 27-2033

  • Provide an adequate supply of heat for the apartment in the entire apartment, 3rd story at north

    Issued 29 Nov 2020Violation closed 6 Jun 2021Heat and hot water§ 27-2029

  • Provide ready access to buildings heating system door locked at cellar

    Issued 29 Nov 2020Violation closed 6 Jun 2021Heat and hot water§ 27-2033

  • Arrange and make self-closing the doors at bulkhead stairs to roof, 3rd story

    Issued 2 Mar 2020Violation closed 6 Jun 2021Fire and safety equipment§ 27-2005 +1

  • Properly repair the source and abate the evidence of a water leak at ceiling at cellar north at west

    Issued 2 Mar 2020Violation closed 6 Jun 2021Leaks and plumbing§ 27-2026

  • Remove all obstructions and repair all defects in at house trap cellar north at west

    Issued 2 Mar 2020Violation closed 6 Jun 2021§ 27-2026

  • Remove disused plumbing fixtures and properly seal pipe connections water closet and sink at cellar west

    Issued 2 Mar 2020Violation closed 6 Jun 2021Leaks and plumbing§ 27-2026

  • Remove all encumbrances consisting of household items at bulk head stairs to roof, 3rd story

    Issued 2 Mar 2020Violation closed 6 Jun 2021Fire and safety equipment§ 27-2005 +1

  • Properly repair with similar material the broken or defective fire retardant plaster at ceiling & all walls at cellar public stair

    Issued 27 Feb 2020Violation closed 6 Jun 2021Floors and stairs§ 27-2005

  • Dept. rules and regulations. remove the encumbrance obstructing egress from fire escapes household items on front all stories at fire escape

    Issued 27 Feb 2020Violation closed 6 Jun 2021Fire and safety equipment§ 27-2005 +1

  • Arrange and make self-closing the doors at the building front entrance

    Issued 27 Feb 2020Violation closed 6 Jun 2021Fire and safety equipment§ 27-2005 +1

  • Properly repair with similar material the broken or defective retaining concrete wall at west at air shaft

    Issued 27 Feb 2020Violation closed 6 Jun 2021Walls and ceilings§ 27-2005

  • Properly repair with similar material the broken or defective 1st wood tread from bottom, public stairs, cellar story

    Issued 21 Feb 2020Violation closed 6 Jun 2021Floors and stairs§ 27-2005

  • Properly repair with similar material the broken or defective soffit, north and west walls with fire retardant materials, public stairs, cellar story

    Issued 21 Feb 2020Violation closed 6 Jun 2021Floors and stairs§ 27-2005

  • Remove disused plumbing fixtures and properly seal pipe connections sink at east wall, water closet at south wall, at cellar center

    Issued 21 Feb 2020Violation closed 6 Jun 2021Leaks and plumbing§ 27-2026

Showing the 100 most recent of 162.

239 violations on record in total, 67 of them open. The count at the top of this page counts habitability violations only.

Complaints to the city

Public complaint

Complaints are reports made to the city. They are not confirmed findings. They come from HPD and from 311, and the same problem can appear more than once if more than one neighbour called.

15 complaints in three years, 1 of them in the last twelve months.

  • Pests1 / 5
  • Electrical0 / 3
  • Heat and hot water0 / 2
  • Mold and damp0 / 2
  • Walls and ceilings0 / 2
  • Leaks and plumbing0 / 1

Last twelve months / last three years. The solid part of each bar is the last twelve months.

Court records

Court record

Housing Court cases

Cases the city’s housing department (HPD) brought against the owner, usually to force repairs or restore heat. A case is an allegation; where the court recorded an outcome, it is shown.

7 cases, all closed.

  • Access Warrant - Non-Lead

    Opened 21 Jan 2025

  • Comprehensive

    Opened 1 Dec 2023Judgment entered

  • Heat and Hot Water

    Opened 8 Sept 2022

  • Heat and Hot Water

    Opened 5 Feb 2021

  • Heat and Hot Water

    Opened 11 Mar 2020

  • Heat and Hot Water

    Opened 14 Aug 2019

  • Tenant Action/Harassment

    Opened 19 Apr 2011

Evictions

Residential evictions carried out by a city marshal since 2017. Most follow a case for unpaid rent, so a count here is not by itself a finding about the building or the landlord. We show how many, never which apartment.

No marshal evictions recorded at this building since 2017.

Filings

Public filing

Building permits

No DOB permits filed for this building in the last five years.

Annual bedbug report

Every multiple dwelling in New York must file this once a year. A report of zero infested units is good news. No report is not: failing to file is itself a violation.

  • 2021No infested units reported (2019 report)

Ownership and management

Public filing

Associations come from registration records and may be incomplete. Owners register with HPD once a year, so a change of hands can go unrecorded for a full cycle.

The most recent registration on file for this address expired 31 Aug 2022 and has not been renewed since, so it is more than a full cycle old. Whoever is named below may no longer be responsible for the building.

  • Owner of record and managing agent

    72-14 69TH LLC

    Public records list 72-14 69TH LLC as the owner of record and the registered managing agent for this address as of 8 Nov 2021. Source: HPD registration.

Wrong company, wrong date, or a change that is not reflected here? Report a correction.

What to ask at the viewing

Drawn from this building’s record above. They are questions, not conclusions: the point is to find out, in the twenty minutes you get inside, what the public record cannot tell you.

  1. The city currently has 16 open immediately-hazardous violations on this building. Ask which apartments they concern, how many are in the one you would be renting, and when HPD re-inspects.
  2. There are 2 open mould violations on record. Ask to look behind furniture and under sinks, and ask what was done the last time; a repaint is not a repair.
  3. There was 1 pest complaint here in the last twelve months. The owner has filed a bedbug report for this building (most recently for the year ending 2021). Ask when the building was last treated, how often an exterminator comes, and whether treatment covers the whole line of apartments or only the one that complained.
  4. Leaks and plumbing come up on this building's record. Ask which apartments were affected and whether the cause was ever found: 0 complaints in the last twelve months.
  5. Ask what the deposit is, exactly what can be deducted from it, and how and when it comes back.
  6. Ask who to call when something breaks, what happens after hours and at weekends, and how long a repair normally takes.

Ask for anything that matters in writing; an email after the viewing is enough. We are not your lawyer and this is not legal advice.

Questions about this building

BBL 4037040025 · Block 3704, Lot 25 · Building class C2