ByTenantsByTenants home

28-07 38 Street, Astoria, NY 11103

Built 1912 · 4-story walk-up · 8 apartments

7 immediately hazardous violations open. 10 open in all. On the state's rent-stabilization list for 2024.

Tenant reviews
None yetLived here? Reviews open soon.
Open violations
107 · 3
Public record
Updated todayFrom the city’s own data (, 311, the courts), refreshed nightly.

Violations issued each year

Violations issued each year
YearHazardousNon-hazardous
202200
2023171
2024140
2025163
2026 so far120

Plus 132 violations from 1990 to 2021. Counted when issued, whether open or fixed since. Paperwork left out.

See every violation
Found most often since 2022
  • Fire and safety equipment 21
  • Floors and stairs 19
  • Roof and outside the building 6
Open per apartment
1.3 (10 open across 8 apartments)
Inspector last found a problem
15 Sept 2026 (visits that find nothing are not published)
What do these labels mean?
Tenant-reported
A resident's firsthand account of living here, moderated before it publishes, and labelled with whether we verified they lived there.
Official violation
A city inspector visited and recorded a code violation. HPD's own words, and its own hazard class.
Public complaint
A complaint somebody made to a city system, through HPD or 311. A report, not a finding: nobody has necessarily inspected it.
Public filing
A permit, a registration, a bedbug report: a document the owner filed with the city because the law requires it.
Court record
A Housing Court case HPD brought against the owner, or an eviction a city marshal carried out. A court's record: a case is an allegation until it ends in a finding.
Insufficient data
Not enough current information here to infer a pattern either way.

Tenant reviews

Tenant-reported

No tenant reviews yet. Lived here? Be the first.

Nothing above this section came from a tenant. It is all filed by the city, which means it only holds what somebody reported and an inspector wrote down, not what it is actually like to live here.

Not open yet. Reviews open when this neighbourhood does.

Heat season

Last winter (2025–26), the city received heat or hot-water complaints about this building on 1 day.

WinterDaysComplaintsViolations
2025–26110

The rules, 1 October to 31 May: from 6am to 10pm, when it is below 55°F outside, the apartment must be at least 68°F; overnight it must be at least 62°F whatever the weather. Hot water must be at least 120°F all year. A tenant without heat can report it to 311.

Rent stabilization

Public filing

The owner registered at least one rent-stabilized apartment here with the state for 2024. The list does not say which apartments, or how many.

Source: Rent Guidelines Board building list, from the state's 2024 registrations. To know about one apartment, a tenant can ask the state for its rent history through Ask HCR.

City violations

Official violation

Immediately hazardous7 open

Class C. HPD considers the condition an immediate danger: no heat in winter, no hot water, lead paint where a child lives, a broken lock on the front door. The owner has 24 hours to correct it.

  • Abate the infestation consisting of mice in the entire apartment, 2nd story at south

    Issued 24 Mar 2026Defect letter issued 17 Sept 2026Pests§ 27-2017.4

  • Abate the infestation consisting of roaches in the entire apartment, 2nd story at south

    Issued 24 Mar 2026Defect letter issued 17 Sept 2026Pests§ 27-2017.4

  • Correct the lead-based paint hazard - paint that tested positive for lead content and that is peeling or on a deteriorated subsurface - using work practices set forth in 28 rcny §11-06(b)(2) north wall in the 1st room from east, 4th story at south

    Issued 20 Apr 2016First no access to re- inspect violation 24 Sept 2026Lead paint§ 27-2056.6

  • Correct the lead-based paint hazard - presumed lead paint that is peeling or on a deteriorated subsurface using work practices set forth in 28 rcny §11-06(b)(2) 1st radiator from west at north wall in the 2nd room from east, 4th story at south

    Issued 29 Feb 2016First no access to re- inspect violation 24 Sept 2026Lead paint§ 27-2056.6

  • Correct the lead-based paint hazard - paint that tested positive for lead content and that is peeling or on a deteriorated subsurface - using work practices set forth in 28 rcny §11-06(b)(2) 1st door frame from north at east wall in the 4th room from east, 4th story at south

    Issued 25 Feb 2016First no access to re- inspect violation 24 Sept 2026Lead paint§ 27-2056.6

  • Correct the lead-based paint hazard - paint that tested positive for lead content and that is peeling or on a deteriorated subsurface - using work practices set forth in 28 rcny §11-06(b)(2) north wall, south wall in the 2nd room from east, 4th story at south

    Issued 26 Aug 2014First no access to re- inspect violation 24 Sept 2026Lead paint§ 27-2056.6

  • Correct the lead-based paint hazard - paint that tested positive for lead content and that is peeling or on a deteriorated subsurface - using work practices set forth in 28 rcny §11-06(b)(2) ceiling in the 2nd room from east, 4th story at south

    Issued 30 May 2013First no access to re- inspect violation 24 Sept 2026Lead paint§ 27-2056.6

Hazardous3 open

Class B. A hazardous condition: a leak, mould, a defective floor. The owner has 30 days to correct it.

  • Properly repair or replace the broken or defective latch assembly on door in the entrance, 4th story at north

    Issued 15 Sept 2026Civ14 mailed 30 Sept 2026Doors and windows§ 27-2005

  • Properly repair or replace the broken or defective latch assembly on door in the entrance, 2nd story at south

    Issued 15 Sept 2026Civ14 mailed 30 Sept 2026Doors and windows§ 27-2005

  • Trace and repair the source and abate the visible mold condition... approx 12 sq. ft at ceiling in the bathroom, 2nd story

    Issued 1 Mar 2020Defect letter issued 24 Sept 2026Mold and damp§ 27-2017.3

185 closed violations, plus 12 closed paperwork filings

Closed means HPD recorded the violation as corrected, or dismissed it. Both appear here, because the difference matters and only HPD’s own status line says which it was.

  • Replace or repair the self-closing doors that is missing or defective latch in the entrance, 4th story at north

    Issued 15 Sept 2026Violation closed 2 Oct 2026Fire and safety equipment§ 27-2005 +3

  • Remove the illegal fastening consisting of self lockable panic bar installed on bulkhead door to roof at public hall, 4th story

    Issued 15 Sept 2026Violation closed 2 Oct 2026Roof and outside the building§ 27-2005 +1

  • Abate the nuisance consisting of key operated lock installed on entrance door to room with fire esacape window in the 5th room from north, 4th story at north

    Issued 15 Sept 2026Violation closed 2 Oct 2026Doors and windows§ 27-2005 +1

  • Replace or repair the self-closing doors that is missing or defective latch in the entrance, 2nd story at south

    Issued 15 Sept 2026Violation closed 2 Oct 2026Fire and safety equipment§ 27-2005 +3

  • Properly repair the broken or defective turn knobs at shower body in bathtub in the bathroom, 3rd story at west

    Issued 28 Jun 2013Violation closed 24 Sept 2026Leaks and plumbing§ 27-2005

  • Properly repair with similar material the broken or defective wood floor in the kitchen, 2nd story at south

    Issued 24 Mar 2026Violation closed 17 Sept 2026Floors and stairs§ 27-2005

  • Remove all obstructions and repair all defects in at bathtub waste line in the bathroom, 2nd story at south

    Issued 24 Mar 2026Violation closed 17 Sept 2026Leaks and plumbing§ 27-2026

  • Repair, replace or provide an approved and operational carbon monoxide detecting device, installed in accordance with applicable law and rules missng in the entire apartment, 2nd story at south

    Issued 24 Mar 2026Violation closed 17 Sept 2026Fire and safety equipment§ 27-2045 +3

  • Repair, replace or provide an approved and operational smoke detecting device, installed in accordance with department of buildings rules and regulations missing in the entire apartment, 2nd story at south

    Issued 24 Mar 2026Violation closed 17 Sept 2026Fire and safety equipment§ 27-2045 +2

  • Repair the broken or defective plastered surfaces and paint in a uniform color at west wall in the 4th room from east, 4th story at north

    Issued 15 May 2023Violation closed 17 Sept 2026Walls and ceilings§ 27-2005

  • Properly repair with similar material the broken or defective wood floor in the private hallway, 2nd story at south

    Issued 27 Aug 2009Violation closed 17 Sept 2026Floors and stairs§ 27-2005

  • Properly repair or replace the broken or defective latch in the entrance, 4th story at west

    Issued 29 Dec 2024Violation closed 31 Mar 2026§ 27-2005

  • Replace or repair the self-closing doors that is missing or defective latch in the entrance, 4th story at west

    Issued 29 Dec 2024Violation closed 31 Mar 2026Fire and safety equipment§ 27-2005 +3

  • Properly repair or replace the broken or defective latch at fire escape window in the 1st room from east, 4th story at south

    Issued 22 May 2023Violation closed 31 Mar 2026Fire and safety equipment§ 27-2005

  • Replace or repair the self-closing doors that is missing or defective at apartment in the entrance, 2nd story at north

    Issued 15 May 2023Violation closed 31 Mar 2026Fire and safety equipment§ 27-2005 +3

  • Refit lower window sash at west in the 6th room from east, 2nd story at north

    Issued 15 May 2023Violation closed 31 Mar 2026Doors and windows§ 27-2005

  • Replace or repair the self-closing doors that is missing or defective at 1st story public door leading to cellar, 1st story

    Issued 15 May 2023Violation closed 31 Mar 2026Fire and safety equipment§ 27-2005 +3

  • Replace or repair the self-closing doors that is missing or defective at boiler room door at cellar

    Issued 15 May 2023Violation closed 31 Mar 2026Fire and safety equipment§ 27-2005 +3

  • Refit lower window sash in the kitchen, 2nd story at north

    Issued 15 May 2023Violation closed 31 Mar 2026Doors and windows§ 27-2005

  • Properly repair the broken or defective lower sash of window at north wall in the 2nd room from east, 2nd story

    Issued 2 Mar 2020Violation closed 31 Mar 2026Doors and windows§ 27-2005

  • Properly repair the broken or defective lower sash window counter balance in the 4th room from east, 4th story at south

    Issued 10 Mar 2016Violation closed 31 Mar 2026Doors and windows§ 27-2005

  • Replace with new the broken or defective counter balances at lower sash, east window in the 4th room from east, 4th story at south

    Issued 26 Feb 2016Violation closed 31 Mar 2026Doors and windows§ 27-2005

  • Provide approved metal screen at skylight at bulkhead at roof

    Issued 26 Sept 2025Violation closed 25 Mar 2026Roof and outside the building§ 27-2005

  • Paint with light colored paint to the satisfaction of this department at south wall at public hall, 1st story

    Issued 26 Sept 2025Violation closed 25 Mar 2026Walls and ceilings§ 27-2013

  • Paint with light colored paint to the satisfaction of this department at east wall at intermediate landing at public hall stairs, 2nd story

    Issued 26 Sept 2025Violation closed 25 Mar 2026Floors and stairs§ 27-2013

  • Provide approved metal screen below skylight at bulkhead

    Issued 11 Sept 2025Violation closed 25 Mar 2026Roof and outside the building§ 27-2005

  • Provide dwelling with a janitor or responsible person or janitorial service.

    Issued 11 Sept 2025Violation closed 25 Mar 2026Super and management§ 27-2053

  • Cleanse to the satisfaction of this department the treads and landing at public hall stairs, 4th story

    Issued 29 Aug 2025Violation closed 25 Mar 2026Floors and stairs§ 27-2011

  • Repair the flushing apparatus and maintain same so as to flush effectively the water closet. in the bathroom, 4th story at north

    Issued 2 Dec 2024Violation closed 25 Mar 2026§ 27-2026

  • Remove the illegal fastening consisting of lockable hasp and eye installed at bulkhead door at public hall, 4th story

    Issued 2 Dec 2024Violation closed 25 Mar 2026Doors and windows§ 27-2005 +1

  • Replace or repair the self-closing doors that is missing or defective bulkhead door hinges at public hall, 4th story

    Issued 11 Dec 2023Violation closed 25 Mar 2026Fire and safety equipment§ 27-2005 +3

  • Properly repair or replace the broken or defective bulkhead door to roof at public hall, 4th story

    Issued 22 May 2023Violation closed 25 Mar 2026Roof and outside the building§ 27-2005

  • Repair the roof so that it will not leak over ceiling in the 4th room from east, 4th story at north

    Issued 15 May 2023Violation closed 25 Mar 2026Leaks and plumbing§ 27-2005

  • Abate the nuisance consisting of key operated lock installed at door leading to fire escape window in the 1st room from east, 2nd story at south

    Issued 15 May 2023Violation closed 25 Mar 2026Fire and safety equipment§ 27-2005 +1

  • Abate the nuisance consisting of air conditioner installed at fire escape window in the 1st room from east, 2nd story at south

    Issued 15 May 2023Violation closed 25 Mar 2026Fire and safety equipment§ 27-2005 +1

  • Properly repair with similar material the broken or defective wood frame at west wall in the 4th room from east, 4th story at north

    Issued 15 May 2023Violation closed 25 Mar 2026Walls and ceilings§ 27-2005

  • Replace or repair the self-closing doors that is missing or defective at building entrance door, 1st story

    Issued 15 May 2023Violation closed 25 Mar 2026Fire and safety equipment§ 27-2005 +3

  • Replace or repair the self-closing doors that is missing or defective at apartment in the entrance, 4th story at north

    Issued 15 May 2023Violation closed 25 Mar 2026Fire and safety equipment§ 27-2005 +3

  • Repair or replace the carbon monoxide detecting device(s). missing in the entire apartment, 4th story

    Issued 29 Mar 2018Violation closed 25 Mar 2026Fire and safety equipment§ 27-2046.1

  • Repair or replace the smoke detector missing in the entire apartment, 4th story

    Issued 29 Mar 2018Violation closed 25 Mar 2026Fire and safety equipment§ 27-2045

  • Paint with light colored paint to the satisfaction of this department ceiling in the bathroom, 2nd story at south

    Issued 24 Feb 2011Violation closed 25 Mar 2026Walls and ceilings§ 27-2013

  • Abate the nuisance consisting of concealed water leak at ceiling in the bathroom, 2nd story

    Issued 1 Aug 2009Violation closed 25 Mar 2026Leaks and plumbing§ 27-2005 +1

  • Repair the broken or defective plastered surfaces and paint in a uniform color walls & ceiling in the bathroom, 2nd story

    Issued 1 Aug 2009Violation closed 25 Mar 2026Walls and ceilings§ 27-2005

  • Trace and repair the source and abate the nuisance consisting of mold... ceiling in the bathroom, 2nd story

    Issued 1 Aug 2009Violation closed 25 Mar 2026Mold and damp§ 27-2005

  • Replace with new the missing baluster 30th from bottom up at public hall stairs, 4th story

    Issued 11 Sept 2025Violation closed 12 Mar 2026Floors and stairs§ 27-2005

  • Replace with new the missing 7th baluster from bottom up at public hall stairs, 2nd story

    Issued 11 Sept 2025Violation closed 12 Mar 2026Floors and stairs§ 27-2005

  • Properly secure the loose baluster 23rd from bottom up at public hall stairs, 4th story

    Issued 11 Sept 2025Violation closed 12 Mar 2026Floors and stairs§ 27-2005

  • Replace with new the missing baluster 15th from bottom up from intermediate landing at public hall stairs, 4th story

    Issued 29 Aug 2025Violation closed 12 Mar 2026Floors and stairs§ 27-2005

  • Replace with new the missing baluster 7th from bottom up at public hall stairs, 2nd story

    Issued 29 Aug 2025Violation closed 12 Mar 2026Floors and stairs§ 27-2005

  • Properly secure the loose baluster 8th from bottom up from intermediate landing at public hall stairs, 4th story

    Issued 29 Aug 2025Violation closed 12 Mar 2026Floors and stairs§ 27-2005

  • Properly repair or replace the broken or defective counter balance at lower window sash at fire escape window in the 1st room from east, 2nd story at north

    Issued 15 May 2023Violation closed 17 Jan 2026Fire and safety equipment§ 27-2005

  • Provide operable knob at door at bulkhead allowing re-entry from roof to bulkhead

    Issued 11 Sept 2025Violation dismissed 25 Dec 2025Roof and outside the building§ 27-2005

  • Properly repair with similar material the broken or defective wood tread 16th, 17th, 18th and 19th tread from bottom up at public hall stairs, 4th story

    Issued 11 Sept 2025Violation closed 10 Nov 2025Floors and stairs§ 27-2005

  • Properly repair or replace the broken or defective wood nosing at intermediate landing at public hall stairs, 4th story

    Issued 11 Sept 2025Violation closed 10 Nov 2025Floors and stairs§ 27-2005

  • Replace or repair the self-closing doors that is missing or defective hinges at door at vestibule, 1st story

    Issued 29 Aug 2025Violation closed 10 Nov 2025Fire and safety equipment§ 27-2005 +3

  • Replace or repair the self-closing doors that is missing or defective hinges at door at roof

    Issued 29 Aug 2025Violation closed 10 Nov 2025Fire and safety equipment§ 27-2005 +3

  • Remove the illegal fastening locking device at bulkhead door at roof

    Issued 26 Sept 2025Violation closed 22 Oct 2025Roof and outside the building§ 27-2005 +1

  • Properly repair or replace the broken or defective 8th wood tread from the bottom up at public hall stairs, 4th story

    Issued 26 Sept 2025Violation closed 22 Oct 2025Floors and stairs§ 27-2005

  • Properly repair or replace the broken or defective wood balluster 1st from west on north balustrade at public hall stairs, 3rd story

    Issued 2 Dec 2024Violation closed 30 Jun 2025Floors and stairs§ 27-2005

  • Replace or repair the self-closing doors that is missing or defective hinges bulkhead at public hall, 4th story

    Issued 2 Dec 2024Violation closed 30 Jun 2025Fire and safety equipment§ 27-2005 +3

  • Replace with new the missing wood balluster 4th and 5th from east on south balustrade at public hall stairs, 2nd story

    Issued 2 Dec 2024Violation closed 30 Jun 2025Floors and stairs§ 27-2005

  • Properly repair with similar material the broken or defective wood landing bulkhead stairs, 4th story

    Issued 2 Dec 2024Violation closed 30 Jun 2025Floors and stairs§ 27-2005

  • Properly repair with similar material the broken or defective wood intermediate landing bulkhead stairs, 4th story

    Issued 2 Dec 2024Violation closed 30 Jun 2025Floors and stairs§ 27-2005

  • Replace with new the missing wood balluster 2nd from west at north balustrade on bulkhead stairs, 4th story

    Issued 2 Dec 2024Violation closed 30 Jun 2025Floors and stairs§ 27-2005

  • Properly repair or replace the broken or defective wood balluster 3rd and 9th from west at north balustrade on bulkhead stairs, 4th story

    Issued 2 Dec 2024Violation closed 30 Jun 2025Floors and stairs§ 27-2005

  • Properly repair with similar material the broken or defective wood tread 5th from bottom after intermediate landing bulkhead stairs, 4th story

    Issued 2 Dec 2024Violation closed 30 Jun 2025Floors and stairs§ 27-2005

  • Repair or replace the smoke detector defective in the entire apartment, 4th story at north

    Issued 2 Dec 2024Violation dismissed 3 Apr 2025Fire and safety equipment§ 27-2045

  • Repair or replace the carbon monoxide detecting device(s). defective in the entire apartment, 4th story at north

    Issued 2 Dec 2024Violation dismissed 3 Apr 2025Fire and safety equipment§ 27-2046.1

  • Replace or repair the self-closing doors that is missing or defective at apartment in the entrance, 2nd story at south

    Issued 15 May 2023Violation closed 4 Feb 2024Fire and safety equipment§ 27-2005 +3

  • Properly repair and abate unsafe electric wiring condition consisting of extension cord installed from cellar to 4th story at public halll, 1st story

    Issued 15 May 2023Violation closed 26 Jun 2023Electrical§ 27-2005

  • Paint with light colored paint to the satisfaction of this department.. south wall in the 1st room from east, 4th story at south

    Issued 21 Apr 2016Violation closed 23 May 2023Walls and ceilings§ 27-2013

  • Remove the illegal fastening a key operated door knob lock obstructing egress to the fire escape window in the 1st room from east, 4th story at south

    Issued 12 Apr 2016Violation closed 23 May 2023Fire and safety equipment§ 27-2005 +1

  • Install the missing or repair/replace the defective window guard(s) in accordance with the specifications of the new york city health code section 24 rcny chapter 12. wg to install = 0; wg to replace = 0; wg to repair = 2; in the entire apartment, 4th story at south

    Issued 10 Mar 2016Violation closed 23 May 2023Fire and safety equipment§ 27-2043.1

  • Properly repair and abate unsafe electric wiring condition consisting of ceiling electric light fixture in the 1st room from east, 4th story at south

    Issued 26 Feb 2016Violation closed 23 May 2023Electrical§ 27-2005

  • Repair the roof so that it will not leak... in the foyer, 4th story at south

    Issued 26 Feb 2016Violation closed 23 May 2023Leaks and plumbing§ 27-2005

  • Repair the roof so that it will not leak,,, ceiling in the 6th room from east, 4th story at south

    Issued 26 Feb 2016Violation closed 23 May 2023Leaks and plumbing§ 27-2005

  • Repair the broken or defective plastered surfaces and paint in a uniform color, ceiling in the 4th room from east, 4th story at south

    Issued 26 Feb 2016Violation closed 23 May 2023Walls and ceilings§ 27-2005

  • Repair the broken or defective plastered surfaces and paint in a uniform color ceiling in the 4th room from east, 4th story at south

    Issued 30 Nov 2006Violation closed 23 May 2023Walls and ceilings§ 27-2005

  • Repair the broken or defective plastered surfaces and paint in a uniform color north wall in the 2nd room from east, 2nd story

    Issued 2 Mar 2020Violation closed 15 May 2023Walls and ceilings§ 27-2005

  • Repair the broken or defective plastered surfaces and paint in a uniform color ceiling in the kitchen, 2nd story

    Issued 2 Mar 2020Violation closed 15 May 2023Walls and ceilings§ 27-2005

  • Repair the broken or defective plastered surfaces and paint in a uniform color ceiling and south wall in the bathroom, 2nd story

    Issued 2 Mar 2020Violation closed 15 May 2023Walls and ceilings§ 27-2005

  • Provide ready access to buildings heating system locked boiler room

    Issued 2 Mar 2020Violation closed 15 May 2023Heat and hot water§ 27-2033

  • Repair the broken or defective plastered surfaces and paint in a uniform color ceiling in the 4th room from east, 2nd story

    Issued 2 Mar 2020Violation closed 15 May 2023Walls and ceilings§ 27-2005

  • Repair the broken or defective plastered surfaces and paint in a uniform color ceiling in the 1st room from east, 2nd story

    Issued 2 Mar 2020Violation closed 15 May 2023Walls and ceilings§ 27-2005

  • Replace with new the broken or defective wire glass in the door in the entrance, 4th story

    Issued 28 Sept 2015Violation closed 15 May 2023Doors and windows§ 27-2005

  • Properly repair the broken or defective intercom system from vestibule to in the entire apartment, 4th story

    Issued 2 May 2015Violation closed 15 May 2023Entry, buzzer and mail§ 27-2005

  • Properly repair with similar material the broken or defective wood floor in the 4th room from east, 2nd story at south

    Issued 27 Aug 2009Violation closed 15 May 2023Floors and stairs§ 27-2005

  • Properly repair with similar material the broken or defective wood floor in the 6th room from east, 2nd story at south

    Issued 27 Aug 2009Violation closed 15 May 2023Floors and stairs§ 27-2005

  • Paint metal in accordance with dept. regulation heat riser in the bathroom, 2nd story

    Issued 1 Aug 2009Violation closed 15 May 2023Heat and hot water§ 27-2005

  • Arrange and make self-closing the doors entrance, 2nd story

    Issued 2 Mar 2020Violation dismissed 31 May 2020Fire and safety equipment§ 27-2005 +1

  • Repair or replace the smoke detector defective, 2nd story

    Issued 2 Mar 2020Violation dismissed 31 May 2020Fire and safety equipment§ 27-2045

  • Repair or replace the carbon monoxide detecting device(s). defective, 2nd story

    Issued 2 Mar 2020Violation dismissed 31 May 2020Fire and safety equipment§ 27-2046.1

  • Properly repair the broken or defective vestibule door lock set, 1st story

    Issued 21 Jan 2020Violation dismissed 26 Apr 2020Doors and windows§ 27-2005

  • Provide hot water at all hot water fixtures, 2nd story

    Issued 2 Mar 2020Violation closed 31 Mar 2020Heat and hot water§ 27-2031

  • Replace with new the broken or defective wood door jamb and striker plate in the entrance, 4th story

    Issued 29 Mar 2018Violation closed 4 Apr 2018Doors and windows§ 27-2005

  • Replace with new the missing door lock mechanism in the entrance, 4th story

    Issued 29 Mar 2018Violation closed 4 Apr 2018Doors and windows§ 27-2005

  • Paint with light colored paint to the satisfaction of this department the 1st door frame from north at east wall in the 6th room from east, 4th story at south

    Issued 19 May 2015Violation dismissed 15 Dec 2016Doors and windows§ 27-2013

  • Paint with light colored paint to the satisfaction of this department the 1st door from west at north wall in the private hallway, 4th story at south

    Issued 19 May 2015Violation dismissed 15 Dec 2016Doors and windows§ 27-2013

  • Paint with light colored paint to the satisfaction of this department the ceiling, 1st window frame from north at east wall in the 4th room from east, 4th story at south

    Issued 19 May 2015Violation dismissed 15 Dec 2016Doors and windows§ 27-2013

  • Paint with light colored paint to the satisfaction of this department the 1st door frame from south at west wall in the 3rd room from east, 4th story at south

    Issued 15 Jul 2013Violation dismissed 15 Dec 2016Doors and windows§ 27-2013

Showing the 100 most recent of 185.

207 violations on record in total, 10 of them open. The count at the top of this page counts habitability violations only.

Complaints to the city

Public complaint

Complaints are reports made to the city. They are not confirmed findings. They come from HPD and from 311, and the same problem can appear more than once if more than one neighbour called.

27 complaints in three years, 2 of them in the last twelve months.

  • Heat and hot water1 / 14
  • Leaks and plumbing0 / 6
  • Pests0 / 3
  • Walls and ceilings0 / 2
  • Noise1 / 1
  • Other0 / 1

Last twelve months / last three years. The solid part of each bar is the last twelve months.

Court records

Court record

Housing Court cases

Cases the city’s housing department (HPD) brought against the owner, usually to force repairs or restore heat. A case is an allegation; where the court recorded an outcome, it is shown.

No HPD Housing Court cases on record for this building.

Evictions

Residential evictions carried out by a city marshal since 2017. Most follow a case for unpaid rent, so a count here is not by itself a finding about the building or the landlord. We show how many, never which apartment.

No marshal evictions recorded at this building since 2017.

Filings

Public filing

Building permits

No DOB permits filed for this building in the last five years.

Annual bedbug report

Every multiple dwelling in New York must file this once a year. A report of zero infested units is good news. No report is not: failing to file is itself a violation.

  • 2026No infested units reported (2024 report)
Show 4 earlier reports
  • 2024No infested units reported (2023 report)
  • 2023No infested units reported (2022 report)
  • 2023No infested units reported (2021 report)
  • 2022No infested units reported (2020 report)

Ownership and management

Public filing

Associations come from registration records and may be incomplete. Owners register with HPD once a year, so a change of hands can go unrecorded for a full cycle.

  • Registered managing agent

    PHOENIX MANAGEMENT 23 LLC

    Public records list PHOENIX MANAGEMENT 23 LLC as the registered managing agent for this address as of 28 Jan 2026. Source: HPD registration.

    Other buildings listed under this agent (7 in the records we hold)

    Show 4 more

    No combined rating for this agent yet. A portfolio rating needs at least 5 verified reviews across 2 or more buildings; currently 0.

  • Owner of record

    PISTILLI38TH ST LLC

    Public records list PISTILLI38TH ST LLC as the owner of record for this address as of 28 Jan 2026. Source: HPD registration.

  • Owner of record

    PITILLI 38TH STREET LLC

    Public records list PITILLI 38TH STREET LLC as the owner of record for this address as of 28 Jan 2026. Source: HPD registration.

Wrong company, wrong date, or a change that is not reflected here? Report a correction.

What to ask at the viewing

Drawn from this building’s record above. They are questions, not conclusions: the point is to find out, in the twenty minutes you get inside, what the public record cannot tell you.

  1. The city currently has 7 open immediately-hazardous violations on this building. Ask which apartments they concern, how many are in the one you would be renting, and when HPD re-inspects.
  2. There is 1 open mould violation on record. Ask to look behind furniture and under sinks, and ask what was done the last time; a repaint is not a repair.
  3. The owner has filed a bedbug report for this building (most recently for the year ending 2026). Ask when the building was last treated, how often an exterminator comes, and whether treatment covers the whole line of apartments or only the one that complained.
  4. This building dates from 1912 and has 5 open lead-paint violations on record. If a child under six will live here, ask what testing and remediation has been done and ask for it in writing.
  5. Ask what the deposit is, exactly what can be deducted from it, and how and when it comes back.
  6. Ask who to call when something breaks, what happens after hours and at weekends, and how long a repair normally takes.

Ask for anything that matters in writing; an email after the viewing is enough. We are not your lawyer and this is not legal advice.

Questions about this building

BBL 4006620018 · Block 662, Lot 18 · Building class C1