Open violations
44
Public record
Updated todayFrom the city’s own data (, 311, the courts), refreshed nightly.

Violations issued each year

None issued since 2022. 4 violations before that, the first in 2008.

See every violation
Open per apartment
less than 0.1 (4 open across 384 apartments)
Inspector last found a problem
21 Jan 2010 (visits that find nothing are not published)
What do these labels mean?
Tenant-reported
A resident's firsthand account of living here, moderated before it publishes, and labelled with whether we verified they lived there.
Official violation
A city inspector visited and recorded a code violation. HPD's own words, and its own hazard class.
Public complaint
A complaint somebody made to a city system, through HPD or 311. A report, not a finding: nobody has necessarily inspected it.
Public filing
A permit, a registration, a bedbug report: a document the owner filed with the city because the law requires it.
Court record
A Housing Court case HPD brought against the owner, or an eviction a city marshal carried out. A court's record: a case is an allegation until it ends in a finding.
Insufficient data
Not enough current information here to infer a pattern either way.

Tenant reviews

Tenant-reported

No tenant reviews yet. Lived here? Be the first.

Nothing above this section came from a tenant. It is all filed by the city, which means it only holds what somebody reported and an inspector wrote down, not what it is actually like to live here.

Not open yet. Reviews open when this neighbourhood does.

Heat season

Last winter (2025–26), the city received heat or hot-water complaints about this building on 1 day.

WinterDaysComplaintsViolations
2025–26110

The rules, 1 October to 31 May: from 6am to 10pm, when it is below 55°F outside, the apartment must be at least 68°F; overnight it must be at least 62°F whatever the weather. Hot water must be at least 120°F all year. A tenant without heat can report it to 311.

Rent stabilization

Public filing

This building is not on the state's list of buildings with rent-stabilized apartments for 2024. That is not proof none are: an owner who did not register is missing from the list too.

Source: Rent Guidelines Board building list, from the state's 2024 registrations. To know about one apartment, a tenant can ask the state for its rent history through Ask HCR.

City violations

Official violation

Hazardous4 open

Class B. A hazardous condition: a leak, mould, a defective floor. The owner has 30 days to correct it.

  • Abate the nuisance consisting of concealed water leak at ceiling in the bathroom, 5th story

    Issued 21 Jan 2010Notice sent out 24 Jan 2010Leaks and plumbing§ 27-2005 +1

  • Properly repair with similar material the broken or defective wood base cabinet at wash basin in the bathroom, 5th story

    Issued 21 Jan 2010Notice sent out 24 Jan 2010Walls and ceilings§ 27-2005

  • Repair the broken or defective plastered surfaces and paint in a uniform color walls & ceiling in the bathroom, 5th story

    Issued 21 Jan 2010Notice sent out 24 Jan 2010Walls and ceilings§ 27-2005

  • Abate the nuisance consisting of vermin roaches in the entire apartment, 3rd story at west

    Issued 23 Oct 2008Notice sent out 27 Oct 2008Pests§ 27-2018

15 violations on record in total, 4 of them open. The count at the top of this page counts habitability violations only.

Complaints to the city

Public complaint

Complaints are reports made to the city. They are not confirmed findings. They come from HPD and from 311, and the same problem can appear more than once if more than one neighbour called.

287 complaints in three years, 150 of them in the last twelve months.

  • Noise146 / 272
  • Pests0 / 7
  • Garbage and cleanliness1 / 3
  • Leaks and plumbing0 / 1
  • Heat and hot water1 / 1
  • Other1 / 1
  • Construction and illegal work1 / 1
  • Fire and safety equipment0 / 1

Last twelve months / last three years. The solid part of each bar is the last twelve months.

Court records

Court record

Housing Court cases

Cases the city’s housing department (HPD) brought against the owner, usually to force repairs or restore heat. A case is an allegation; where the court recorded an outcome, it is shown.

2 cases, all closed.

  • Tenant Action

    Opened 6 Jun 2024

  • Tenant Action/Harassment

    Opened 12 May 2014

Evictions

Residential evictions carried out by a city marshal since 2017. Most follow a case for unpaid rent, so a count here is not by itself a finding about the building or the landlord. We show how many, never which apartment.

  • 20263 evictions
  • 20191 eviction
  • 20185 evictions
  • 20174 evictions

Filings

Public filing

Building permits

30 permits currently in force.

  • Structural

    NYCHA BOILER_removal of existing concrete entry stairs, installation of new concrete entry stairs and pads for mech. equipment, mounting of risers to exterior facade of the building

    Issued 19 Mar 2026Expires 3 Dec 2026

  • General Construction

    Replacement of existing condensate pumps and associated piping.

    Issued 19 Mar 2026Expires 3 Dec 2026

  • Structural

    installation of new steel access platforms for new boilers, entry platform and stairs from storage room to boiler room, new concrete pads for mech. equip., temporary shoring of ceiling in coal storage

    Issued 18 Mar 2026Expires 3 Dec 2026

  • Mechanical Systems

    REPLACEMENT OF EXISTING VACUUM AND CONDENSATE PUMPS, INSTALLATION OF COMBUSTION AIR DUCTWORK AND FLUES FOR NEW DOMESTIC AND HOT WATER HEATERS.

    Issued 18 Mar 2026Expires 3 Dec 2026

  • General Construction

    Replacement of existing condensate pumps and associated piping.

    Issued 18 Mar 2026Expires 3 Dec 2026

  • General Construction

    REPLACEMENT STAIRS AND DOORS OF BOILER PLANT AND TANK/PUMP ROOMS IN KIND WITH EXISTING. REPLACEMENT CONCRETE EQUIPMENT PADS. NEW EXTERIOR FLUE ENCLOSURE TO ROOF TOP.

    Issued 18 Mar 2026Expires 3 Dec 2026

  • Structural

    NYCHA BOILER_Removal and replacement of existing condensate pump concrete pads

    Issued 18 Mar 2026Expires 3 Dec 2026

  • Mechanical Systems

    REPLACEMENT OF EXISTING VACUUM AND CONDENSATE PUMPS, INSTALLATION OF COMBUSTION AIR DUCTWORK AND FLUES FOR NEW DOMESTIC AND HOT WATER HEATERS.

    Issued 18 Mar 2026Expires 3 Dec 2026

  • Mechanical Systems

    REPLACEMENT OF EXISTING VACUUM AND CONDENSATE PUMPS, INSTALLATION OF COMBUSTION AIR DUCTWORK AND FLUES FOR NEW DOMESTIC AND HOT WATER HEATERS.

    Issued 18 Mar 2026Expires 3 Dec 2026

  • Structural

    NYCHA BOILER_removal of existing concrete entry stairs, installation of new concrete entry stairs and pads for mech. equipment, mounting of risers to exterior facade of the building

    Issued 18 Mar 2026Expires 3 Dec 2026

  • Mechanical Systems

    REPLACEMENT OF EXISTING VACUUM AND CONDENSATE PUMPS, INSTALLATION OF COMBUSTION AIR DUCT WORK AND FLUES FOR NEW DOMESTIC AND HOT WATER HEATERS.

    Issued 18 Mar 2026Expires 3 Dec 2026

  • General Construction

    REPLACEMENT STAIRS AND DOORS OF BOILER PLANT AND TANK/PUMP ROOMS IN KIND WITH EXISTING. REPLACEMENT CONCRETE EQUIPMENT PADS.

    Issued 18 Mar 2026Expires 3 Dec 2026

  • Mechanical Systems

    REPLACEMENT OF EXISTING VACUUM AND CONDENSATE PUMPS, INSTALLATION OF COMBUSTION AIR DUCTWORK AND FLUES FOR NEW DOMESTIC AND HOT WATER HEATERS.

    Issued 18 Mar 2026Expires 3 Dec 2026

  • Structural

    removal of existing concrete entry stairs, installation of new concrete entry stairs and pads for mech. equipment, mounting of risers to exterior facade of the building

    Issued 18 Mar 2026Expires 3 Dec 2026

  • General Construction

    REPLACEMENT STAIRS AND DOORS OF BOILER PLANT AND TANK/PUMP ROOMS IN KIND WITH EXISTING. REPLACEMENT CONCRETE EQUIPMENT PADS.

    Issued 18 Mar 2026Expires 3 Dec 2026

  • Mechanical Systems

    NYCHA BOILER_REPLACEMENT OF EXISTING VACUUM AND CONDENSATE PUMPS, INSTALLATION OF COMBUSTION AIR DUCTWORK AND FLUES FOR NEW DOMESTIC AND HOT WATER HEATERS.

    Issued 18 Mar 2026Expires 3 Dec 2026

  • Structural

    NYCHA BOILER_removal of existing concrete entry stairs, installation of new concrete entry stairs and pads for mech. equipment, mounting of risers to exterior facade of the building

    Issued 18 Mar 2026Expires 3 Dec 2026

  • General Construction

    REPLACEMENT STAIRS AND DOORS OF BOILER PLANT AND TANK/PUMP ROOMS IN KIND WITH EXISTING. REPLACEMENT CONCRETE EQUIPMENT PADS.

    Issued 18 Mar 2026Expires 3 Dec 2026

  • Structural

    NYCHA BOILER_removal of existing concrete entry stairs, installation of new concrete entry stairs and pads for mech. equipment, mounting of risers to exterior facade of the building

    Issued 18 Mar 2026Expires 3 Dec 2026

  • Mechanical Systems

    NYCHA BOILER_REPLACEMENT OF EXISTING VACUUM AND CONDENSATE PUMPS, INSTALLATION OF COMBUSTION AIR DUCTWORK AND FLUES FOR NEW DOMESTIC AND HOT WATER HEATERS.

    Issued 18 Mar 2026Expires 3 Dec 2026

  • Mechanical Systems

    REPLACEMENT OF EXISTING VACUUM AND CONDENSATE PUMPS, INSTALLATION OF COMBUSTION AIR DUCTWORK AND FLUES FOR NEW DOMESTIC AND HOT WATER HEATERS.

    Issued 18 Mar 2026Expires 3 Dec 2026

  • Solar

    Installation of 41.42 kw solar energy system on roof. No change of occupancy, use or egress

    Issued 4 Mar 2026Expires 26 Feb 2027

  • Solar

    Installation of 43.6 kw solar energy system on roof. No change of occupancy, use or egress

    Issued 4 Mar 2026Expires 26 Feb 2027

  • Solar

    Installation of 77.935 kw solar energy system on roof. No change of occupancy, use or egress

    Issued 4 Mar 2026Expires 26 Feb 2027

  • Solar

    Installation of 38.695 kw solar energy system on roof. no change of occupancy, use or egress

    Issued 4 Mar 2026Expires 26 Feb 2027

  • Solar

    Installation of 42.51 kw solar energy system on roof. No change of occupancy, use or egress.

    Issued 4 Mar 2026Expires 26 Feb 2027

  • Solar

    Installation of 83.385 kw solar energy system on roof. No change of occupancy, use or egress.

    Issued 4 Mar 2026Expires 26 Feb 2027

  • Solar

    Installation of 81.75 kw solar energy system on roof. No change of occupancy, use or egress

    Issued 4 Mar 2026Expires 26 Feb 2027

  • Solar

    Installation of 70.85 kw solar energy system on roof. No change of occupancy, use or egress.

    Issued 3 Mar 2026Expires 26 Feb 2027

  • Sidewalk Shed · Supported Scaffold

    INSTALLATION OF 300PSF SIDEWALK SHED AND PIPE SCAFFOLDING AS PER PLANS. ALL EQUIPMENT SHALL COMPLY WITH CH #33 OF THE NYC CODE 2022. NO CHANGE IN USE, OCCUPANCY OR EGRESS UNDER THIS APPLICATION.

    Issued 8 Dec 2025Expires 8 Dec 2026

Show 30 expired or finished
  • Boiler Equipment

    PLEASE NOTE: 7 boilers were initially approved as part of Boiler Job Q00449518-S5, but only 1 unique boiler ID was generated. We are now submitting the other 6 boilers as part of subsequent filing to generate 6 more boiler IDs. MS filing was also approved

    Issued 15 Oct 2025Expired 25 Nov 2025

  • Sidewalk Shed · Supported Scaffold

    INSTALLATION OF 300PSF SIDEWALK SHED AND PIPE SCAFFOLDING AS PER PLANS. ALL EQUIPMENT SHALL COMPLY WITH CH #33 OF THE NYC CODE 2022. NO CHANGE IN USE, OCCUPANCY OR EGRESS UNDER THIS APPLICATION.

    Issued 24 Sept 2025Expired 16 May 2026

  • Plumbing

    REMOVE AND REPLACE OR PROVIDE NEW SUMP PUMPS AND DISCHARGE LINES.

    Issued 15 Sept 2025Expired 31 Jan 2026

  • Plumbing

    REMOVE AND REPLACE HOT WATER HEATERS AND WATER LINES, RECIRCULATION PUMPS, DRAINS . INSTALL NEW SUMP PUMPS AND DISCHARGE LINES. INSTALL NEW AIR INTAKES AND EXHAUST FOR WATER HEATERS.

    Issued 15 Sept 2025Expired 31 Jan 2026

  • Plumbing

    NYCHA BOILER_REMOVE AND REPLACE HOT WATER HEATERS AND WATER LINES, RECIRCULATION PUMPS, DRAINS . INSTALL NEW SUMP PUMPS AND DISCHARGE LINES. INSTALL NEW AIR INTAKES AND EXHAUST FOR WATER HEATERS.

    Issued 7 Aug 2025Expired 7 Aug 2026

  • Construction Fence

    RAVENSWOOD HOUSES (BUILDING #02), INSTALLATION OF 8 FEET HIGH CONSTRUCTION FENCE IN CONJUNCTION WITH DOB # Q00450564 TO SECURE THE STAGING AREA. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.

    Issued 24 Mar 2025Expired 31 Dec 2025

  • Structural

    NYCHA BOILER_removal of existing concrete entry stairs, installation of new concrete entry stairs and pads for mech. equipment, mounting of risers to exterior facade of the building

    Issued 21 Mar 2025Expired 15 Mar 2026

  • Construction Fence

    RAVENSWOOD HOUSES (BUILDING #03), INSTALLATION OF 8 FEET HIGH CONSTRUCTION FENCE IN CONJUNCTION WITH DOB # Q00454931 TO SECURE THE STAGING AREA. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.

    Issued 17 Mar 2025Expired 31 Dec 2025

  • Construction Fence

    RAVENSWOOD HOUSES (BUILDING #05), INSTALLATION OF 8 FEET HIGH CONSTRUCTION FENCE IN CONJUNCTION WITH DOB # Q00454977 TO SECURE THE STAGING AREA. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.

    Issued 17 Mar 2025Expired 31 Dec 2025

  • Structural

    Temporary shoring scheme to help the roof structure support the loads of the temporary boilers for the duration of the boilers installation. No demolishing or altering the existing structure under this filing.

    Issued 17 Mar 2025Expired 15 Mar 2026

  • Support of Excavation

    INSTALL A 56 1/2'x34'x17' DEEP BRACED INTERLOCKING STEEL SHEET PILE SUPPORT OF EXCAVATION SYSTEM TO FACILITATE THE REMOVAL OF THE EXISTING UNDERGROUND FUEL STORAGE TANKS AT THE RAVENSWOOD HOUSES

    Issued 17 Mar 2025Expired 15 Mar 2026

  • Construction Fence

    RAVENSWOOD HOUSES (BUILDING #8), INSTALLATION OF +/- 180 LINEAR FEET OF CONSTRUCTION FENCE IN CONJUNCTION TO SECURE THE STAGING AREA. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.

    Issued 17 Mar 2025Expired 15 Mar 2026

  • Construction Fence

    RAVENSWOOD HOUSES (BUILDING #1), INSTALLATION OF 8 FEET HIGH CONSTRUCTION FENCE TO SECURE THE STAGING AREA. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.

    Issued 17 Mar 2025Expired 15 Mar 2026

  • Plumbing

    REMOVE AND REPLACE HOT WATER HEATERS AND WATER LINES, RECIRCULATION PUMPS, DRAINS . INSTALL NEW SUMP PUMPS AND DISCHARGE LINES. INSTALL NEW AIR INTAKES AND EXHAUST FOR WATER HEATERS.

    Issued 13 Mar 2025Expired 13 Mar 2026

  • Plumbing

    REMOVE AND REPLACE HOT WATER HEATERS AND WATER LINES, RECIRCULATION PUMPS, DRAINS . INSTALL NEW SUMP PUMPS AND DISCHARGE LINES. INSTALL NEW AIR INTAKES AND EXHAUST FOR WATER HEATERS.

    Issued 13 Mar 2025Expired 13 Mar 2026

  • Plumbing

    Remove gas and water piping from existing heating boilers and provide piping for new boilers. Replace existing steam with new gas-fired water heaters and provide new gas service. Replace sump pumps with new ones. Install temp. piping and water heaters.

    Issued 13 Mar 2025Expired 13 Mar 2026

  • Construction Fence

    RAVENSWOOD HOUSES (BUILDING #06), INSTALLATION OF 8 FEET HIGH CONSTRUCTION FENCE IN CONJUNCTION WITH DOB # Q00455031 TO SECURE THE STAGING AREA. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.

    Issued 8 Jan 2025Expired 15 Mar 2025

  • Support of Excavation

    RAVENSWOOD HOUSES - BUILDING #5, INSTALLATION OF TEMPORARY SHORING AND SUPPORT FOR EXCAVATION IN CONJUNCTION WITH DOB # Q00454977, Q00838442. NO CHANGE IN THE USE, EGRESS, OR OCCUPANCY UNDER THIS APPLICATION.

    Issued 8 Jan 2025Expired 15 Mar 2025

  • Construction Fence

    RAVENSWOOD HOUSES (BUILDING #07), INSTALLATION OF 8 FEET HIGH CONSTRUCTION FENCE IN CONJUNCTION WITH DOB # Q00457470 TO SECURE THE STAGING AREA. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.

    Issued 7 Jan 2025Expired 15 Mar 2025

  • Construction Fence

    RAVENSWOOD HOUSES (BUILDING #04), INSTALLATION OF 8 FEET HIGH CONSTRUCTION FENCE IN CONJUNCTION WITH DOB # Q00454958 TO SECURE THE STAGING AREA. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.

    Issued 7 Jan 2025Expired 15 Mar 2025

  • Boiler Equipment

    NYCHA_Ravenswood Boilers. Install new gas boilers. ALL REMAINING MECHANICAL EQUIPMENT HAS BEEN FILED AND APPROVED UNDER MS JOB FILING Q00449518-S1

    Issued 26 Nov 2024Expired 25 Nov 2025

  • Plumbing

    RAVENSWOOD HOUSES - BUILDING No. 1, INSTALLATION OF TEMPORARY GAS PIPING IN THE BOILER ROOM TO CONNECT 4 MOBILE BOILER TRAILERS TO PROVIDE HEAT DURING THE HEATING SEASON IN CONJUNCTION WITH DOB # Q00449518. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.

    Issued 10 Sept 2024Expired 10 Sept 2025

  • Support of Excavation

    RAVENSWOOD HOUSES - BUILDING #4, INSTALLATION OF TEMPORARY SHORING AND SUPPORT FOR EXCAVATION IN CONJUNCTION WITH DOB # Q00454958, Q00838439. NO CHANGE IN THE USE, EGRESS, OR OCCUPANCY UNDER THIS APPLICATION.

    Issued 25 Jul 2024Expired 1 Jan 2025

  • Support of Excavation

    RAVENSWOOD HOUSES - BUILDING #7, INSTALLATION OF TEMPORARY SHORING AND SUPPORT FOR EXCAVATION IN CONJUNCTION WITH DOB # Q00455168, Q00859086. NO CHANGE IN THE USE, EGRESS, OR OCCUPANCY UNDER THIS APPLICATION.

    Issued 16 Jul 2024Expired 1 Jan 2025

  • Support of Excavation

    RAVENSWOOD HOUSES - BUILDING #6, INSTALLATION OF TEMPORARY SHORING AND SUPPORT FOR EXCAVATION IN CONJUNCTION WITH DOB # Q00455031, Q00838443. NO CHANGE IN THE USE, EGRESS, OR OCCUPANCY UNDER THIS APPLICATION.

    Issued 15 Jul 2024Expired 1 Jan 2025

  • Support of Excavation

    RAVENSWOOD HOUSES - BUILDING #3, INSTALLATION OF TEMPORARY SHORING AND SUPPORT FOR EXCAVATION IN CONJUNCTION WITH DOB # Q00454931, Q00838438. NO CHANGE IN THE USE, EGRESS, OR OCCUPANCY UNDER THIS APPLICATION.

    Issued 12 Jul 2024Expired 1 Jan 2025

  • Support of Excavation

    RAVENSWOOD HOUSES - BUILDING #2, INSTALLATION OF TEMPORARY SHORING AND SUPPORT FOR EXCAVATION IN CONJUNCTION WITH DOB # Q00450564, Q00838431. NO CHANGE IN THE USE, EGRESS, OR OCCUPANCY UNDER THIS APPLICATION.

    Issued 13 May 2024Expired 27 Nov 2024

  • Mechanical Systems

    RAVENSWOOD HOUSES, INSTALLATION OF TEMPORARY BOILER STACKS, STEAM, CONDENSATE, MAKE-UP WATER PIPING CONNECTED TO EXISTING HEATING PLANT TO PROVIDE HEAT DURING THE HEATING SEASON IN CONJUNCTION WITH DOB # Q00449518. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.

    Issued 30 Aug 2023Expired 15 Mar 2024

  • Supported Scaffold

    INSTALLATION OF 3200 SF PIPE SCAFFOLD AT 34-21 21 STREET QUEENS AS INDICATED ON PLANS. THERE WILL BE NO CHANGE IN THE USE, EGRESS, OR OCCUPANCY UNDER THIS APPLICATION

    Issued 1 Dec 2022Expired 11 Nov 2023

  • Supported Scaffold

    PROPOSED INSTALLATION OF PIPE SCAFFOLD FOR REMEDIAL REPAIRS AS PER PLANS. NO CHANGE IN USE OCCUPANCY OR EGRESS UNDER THIS APPLICATION.

    Issued 12 Nov 2022Expired 20 Apr 2023

Annual bedbug report

Every multiple dwelling in New York must file this once a year. A report of zero infested units is good news. No report is not: failing to file is itself a violation.

No bedbug report on file for this building. That usually means the owner did not file one, not that there is nothing to report.

Ownership and management

Public filing

Associations come from registration records and may be incomplete. Owners register with HPD once a year, so a change of hands can go unrecorded for a full cycle.

No current HPD registration for this address. Buildings the owner occupies, and some small ones, are not required to register, but a rental building that should be registered and is not is itself a violation.

Wrong company, wrong date, or a change that is not reflected here? Report a correction.

What to ask at the viewing

Drawn from this building’s record above. They are questions, not conclusions: the point is to find out, in the twenty minutes you get inside, what the public record cannot tell you.

  1. The city has 4 open hazardous violations on this building. Ask which apartments they concern and what has been done since.
  2. 30 active construction permits on file. Ask what is being done, on which floors, and until when, and whether it affects heat, water or the elevator.
  3. Leaks and plumbing come up on this building's record. Ask which apartments were affected and whether the cause was ever found: 0 complaints in the last twelve months.
  4. The building's HPD registration is out of date or names nobody we could identify. Ask who the managing agent is and get a name, a phone number and an address in writing before you sign.
  5. Ask what the deposit is, exactly what can be deducted from it, and how and when it comes back.
  6. Ask who to call when something breaks, what happens after hours and at weekends, and how long a repair normally takes.

Ask for anything that matters in writing; an email after the viewing is enough. We are not your lawyer and this is not legal advice.

Questions about this building

BBL 4005590002 · Block 559, Lot 2 · Building class D7