ByTenantsByTenants home

124 Irving Avenue, Brooklyn, NY 11237

Built 1931 · 4-story walk-up with stores · 7 apartments

25 immediately hazardous violations open. 75 open in all. 1 Housing Court case pending. On the state's rent-stabilization list for 2024.

Tenant reviews
None yetLived here? Reviews open soon.
Open violations
7525 · 38 · 12
Public record
Updated yesterdayFrom the city’s own data (, 311, the courts), refreshed nightly.

Violations issued each year

Violations issued each year
YearHazardousNon-hazardous
2022142
2023262
2024267
202563
2026 so far80

Plus 137 violations from 1993 to 2021. Counted when issued, whether open or fixed since. Paperwork left out.

See every violation
Found most often since 2022
  • Walls and ceilings 19
  • Leaks and plumbing 13
  • Doors and windows 10
Open per apartment
10.7 (75 open across 7 apartments)
Inspector last found a problem
14 Mar 2026 (visits that find nothing are not published)
What do these labels mean?
Tenant-reported
A resident's firsthand account of living here, moderated before it publishes, and labelled with whether we verified they lived there.
Official violation
A city inspector visited and recorded a code violation. HPD's own words, and its own hazard class.
Public complaint
A complaint somebody made to a city system, through HPD or 311. A report, not a finding: nobody has necessarily inspected it.
Public filing
A permit, a registration, a bedbug report: a document the owner filed with the city because the law requires it.
Court record
A Housing Court case HPD brought against the owner, or an eviction a city marshal carried out. A court's record: a case is an allegation until it ends in a finding.
Insufficient data
Not enough current information here to infer a pattern either way.

Tenant reviews

Tenant-reported

No tenant reviews yet. Lived here? Be the first.

Nothing above this section came from a tenant. It is all filed by the city, which means it only holds what somebody reported and an inspector wrote down, not what it is actually like to live here.

Not open yet. Reviews open when this neighbourhood does.

Heat season

Last winter (2025–26), the city received heat or hot-water complaints about this building on 4 days.

WinterDaysComplaintsViolations
2025–26450

The rules, 1 October to 31 May: from 6am to 10pm, when it is below 55°F outside, the apartment must be at least 68°F; overnight it must be at least 62°F whatever the weather. Hot water must be at least 120°F all year. A tenant without heat can report it to 311.

Rent stabilization

Public filing

The owner registered at least one rent-stabilized apartment here with the state for 2024. The list does not say which apartments, or how many.

Source: Rent Guidelines Board building list, from the state's 2024 registrations. To know about one apartment, a tenant can ask the state for its rent history through Ask HCR.

City violations

Official violation

Immediately hazardous25 open

Class C. HPD considers the condition an immediate danger: no heat in winter, no hot water, lead paint where a child lives, a broken lock on the front door. The owner has 24 hours to correct it.

  • Abate the infestation consisting of roaches in the entire apartment, 2nd story at north

    Issued 14 Mar 2026Notice certified late 20 May 2026Pests§ 27-2017.4

  • Properly repair the source and abate the evidence of a water leak over ceiling in the 1st room from north at west, 2nd story at north

    Issued 13 Jan 2026Notice sent out 14 Jan 2026Leaks and plumbing§ 27-2026

  • Repair the broken or defective plastered surfaces and paint in a uniform color at ceiling in the 1st room from north at west, 2nd story at north

    Issued 13 Jan 2026Notice sent out 14 Jan 2026Walls and ceilings§ 27-2005

  • Properly repair the source and abate the evidence of a water leak concealed leak at ceiling and west wall in the 5th room from east at south, 3rd story at west

    Issued 10 Oct 2024Notice sent out 17 Oct 2024Leaks and plumbing§ 27-2026

  • Properly repair with similar material the broken or defective the brick and mortar at west wall 1st, 2nd, 3rd, and 4th stories at building

    Issued 10 Oct 2024Notice sent out 14 Oct 2024Walls and ceilings§ 27-2005

  • Properly repair the source and abate the evidence of a water leak at ceiling in the bathroom, 3rd story at west

    Issued 10 Oct 2024Notice sent out 17 Oct 2024Leaks and plumbing§ 27-2026

  • Properly repair with similar material the broken or defective reglaze bathtub in bathroom in the bathroom, 3rd story at west

    Issued 10 Oct 2024Notice sent out 17 Oct 2024Leaks and plumbing§ 27-2005

  • Correct the lead-based paint hazard - paint that tested positive for lead content and that is peeling or on a deteriorated subsurface - using work practices set forth in 28 rcny §11-06(b)(2) 1st door frame from west at north wall in the 4th room from east at south, 2nd story at west

    Issued 4 Aug 2024Notice sent out 4 Aug 2024Lead paint§ 27-2056.6

  • Correct the lead-based paint hazard - paint that tested positive for lead content and that is peeling or on a deteriorated subsurface - using work practices set forth in 28 rcny §11-06(b)(2) 1st door frame from east at south wall, east wall, 1st window frame from north at east wall, 1st window frame from south at west wall in the 4th room from east at north, 2nd story at west

    Issued 4 Aug 2024Notice sent out 4 Aug 2024Lead paint§ 27-2056.6

  • Abate the infestation consisting of roaches in the entire apartment, 2nd story at west

    Issued 4 Aug 2024Notice certified late 20 May 2026Pests§ 27-2017.4

Show all 25
  • Replace or repair the self-closing doors that is missing or defective entrance door to building from the street, 1st story

    Issued 20 Dec 2023Notice sent out 21 Dec 2023Fire and safety equipment§ 27-2005 +3

  • Provide ready access to buildings heating system door locked at basement

    Issued 20 Nov 2023Notice certified late 5 Dec 2023Heat and hot water§ 27-2033

  • Provide hot water at all hot water fixtures in the entire apartment, 3rd story at south

    Issued 20 Nov 2023Notice certified late 5 Dec 2023Heat and hot water§ 27-2031

  • Post notice, in form approved by the department, stating the name and location of the person designated by the owner to have key to buildings heating system

    Issued 20 Nov 2023Notice certified late 5 Dec 2023Heat and hot water§ 27-2033

  • Install the missing or repair/replace the defective window guard(s) in accordance with the specifications of the new york city health code section 24 rcny chapter 12. wg to install = 2; wg to replace = 0; wg to repair = 0; in the entire apartment, 2nd story at east

    Issued 12 Oct 2023Violation will be reinspected 19 Nov 2023Fire and safety equipment§ 27-2043.1

  • Trace and repair the source and abate the visible mold condition... at the ceiling and all walls in the bathroom, 4th story at west

    Issued 12 Oct 2023Defect letter issued 21 Nov 2023Mold and damp§ 27-2017.3

  • Remove the illegal fastening consisting of a key operated lock on the door leading to the fire escape in the 4th room from east at north, 4th story at west

    Issued 12 Oct 2023Not complied with 21 Nov 2023Fire and safety equipment§ 27-2005 +1

  • Remove the illegal fastening consisting of a dead bolt capable of being padlocked on the door in the entrance, 3rd story at west

    Issued 12 Oct 2023Not complied with 21 Nov 2023Doors and windows§ 27-2005 +1

  • Install the missing or repair/replace the defective window guard(s) in accordance with the specifications of the new york city health code section 24 rcny chapter 12. wg to install = 2, wg to replace = 0, wg to repair = 0 in the entire apartment, 2nd story at east

    Issued 20 Dec 2022First no access to re- inspect violation 21 Nov 2023Fire and safety equipment§ 27-2043.1

  • Replace or repair the self-closing doors that is missing or defective at bulkhead at public hall, 4th story

    Issued 8 Mar 2022Not complied with 21 Nov 2023Fire and safety equipment§ 27-2005 +2

  • Correct the lead-based paint hazard - paint that tested positive for lead content and that is peeling or on a deteriorated subsurface - using work practices set forth in 28 rcny §11-06(b)(2) 2nd window frame from west at north wall, 1st window frame from south at west wall in the 1st room from north at west, 2nd story at north

    Issued 22 Jul 2021Defect letter issued 11 Oct 2023Lead paint§ 27-2056.6

  • Certify compliance with lead-based paint hazard control requirements during period of unit vacancy by performing activities necessary to abate tested lead-based paint from required window and/or door friction surfaces for apartment and make floors smooth and cleanable, positive lead-based paint in an apartment with a child under six, 2nd story at north

    Issued 22 Jul 2021First no access to re- inspect violation 16 Aug 2023Lead paint§ 27-2056.7 +2

  • Correct the lead-based paint hazard - paint that tested positive for lead content and that is peeling or on a deteriorated subsurface - using work practices set forth in 28 rcny §11-06(b)(2) baseboard at north wall, baseboard at south wall, 1st door frame from north at east wall in the foyer, 3rd story at east

    Issued 17 Jan 2018Defect letter issued 27 Sept 2023Lead paint§ 27-2056.6

  • Correct the lead-based paint hazard - paint that tested positive for lead content and that is peeling or on a deteriorated subsurface - using work practices set forth in 28 rcny §11-06(b)(2) north wall, south wall, east wall in the 1st room from east at south, 3rd story at east

    Issued 17 Jan 2018Defect letter issued 21 Nov 2023Lead paint§ 27-2056.6

  • Correct the lead-based paint hazard - paint that tested positive for lead content and that is peeling or on a deteriorated subsurface - using work practices set forth in 28 rcny §11-06(b)(2) 1st window frame from west at north wall in the bathroom, 3rd story at east

    Issued 17 Jan 2018Defect letter issued 27 Sept 2023Lead paint§ 27-2056.6

Hazardous38 open

Class B. A hazardous condition: a leak, mould, a defective floor. The owner has 30 days to correct it.

  • Properly repair with similar material the broken or defective vinyl floor tiles in entire apartment in the entire apartment, 2nd story

    Issued 14 Mar 2026Notice sent out 16 Mar 2026Floors and stairs§ 27-2005

  • Properly repair with similar material the broken or defective refrigerator door gasket in the kitchen, 2nd story at north

    Issued 14 Mar 2026Notice sent out 16 Mar 2026Appliances§ 27-2005

  • Abate the nuisance consisting of plexi-glass at building entrance door, 1st story

    Issued 17 Jan 2026Notice sent out 19 Jan 2026Doors and windows§ 27-2005 +1

  • Properly repair or replace the broken or defective entire mailbox in the vestibule, 1st story

    Issued 17 Jan 2026Notice sent out 19 Jan 2026Entry, buzzer and mail§ 27-2005

  • Trace and repair the source and abate the visible mold condition... greather than 20 sq ft at ceiling in the bathroom, 2nd story at north

    Issued 4 Aug 2025Notice certified late 27 May 2026Mold and damp§ 27-2017.3

  • Trace and repair the source and abate the visible mold condition... less than 10 sqft at ceiling in the bathroom, 2nd story at north original violation 18009290 issued 10-jun-25 has been upgraded to class b per administrative code 27-2017.3a(3)(a) or (b).

    Issued 10 Jun 2025Notice of issuance sent to tenant 13 Oct 2025Mold and damp§ 27-2017.3

  • Properly repair the source and abate the evidence of a water leak above ceiling in the bathroom, 2nd story at north

    Issued 10 Jun 2025Notice sent out 12 Jun 2025Leaks and plumbing§ 27-2026

  • Repair the broken or defective plastered surfaces and paint in a uniform color the ceili g in the bathroom, 2nd story at north

    Issued 9 May 2025Notice sent out 11 May 2025Walls and ceilings§ 27-2005

  • Properly repair or replace the broken or defective entire mailbox at public hall, 1st story

    Issued 5 May 2025Notice sent out 6 May 2025Entry, buzzer and mail§ 27-2005

  • Properly repair with similar material the broken or defective wooden sink base cabinet in the kitchen, 3rd story at west

    Issued 10 Oct 2024Notice sent out 17 Oct 2024Leaks and plumbing§ 27-2005

Show all 38
  • Repair the broken or defective plastered surfaces and paint in a uniform color at ceiling and west wall in the 5th room from east at south, 3rd story at west

    Issued 10 Oct 2024Notice sent out 17 Oct 2024Walls and ceilings§ 27-2005

  • Properly repair the source and abate the evidence of a water leak at ceiling at public hall, 1st story

    Issued 6 Oct 2024Notice sent out 16 Oct 2024Leaks and plumbing§ 27-2026

  • Properly repair with similar material the broken or defective fire retardant plaster at ceiling at public hall, 1st story

    Issued 6 Oct 2024Notice sent out 16 Oct 2024Walls and ceilings§ 27-2005

  • Properly repair or replace the broken or defective mortise lock at entrance door to builidng at public hall, 1st story

    Issued 6 Oct 2024Notice sent out 16 Oct 2024Doors and windows§ 27-2005

  • Properly repair with similar material the broken or defective wood floor in the 4th room from east at north, 2nd story at west

    Issued 4 Aug 2024Notice sent out 4 Aug 2024Floors and stairs§ 27-2005

  • Trace and repair the source and abate the visible mold condition... more than 10 sq feet at the ceiling in the bathroom, 2nd story at west

    Issued 4 Aug 2024Notice certified late 27 May 2026Mold and damp§ 27-2017.3

  • Properly repair the source and abate the evidence of a water leak at the ceiling in the bathroom, 2nd story at west

    Issued 4 Aug 2024Notice sent out 4 Aug 2024Leaks and plumbing§ 27-2026

  • Repair the broken or defective plastered surfaces and paint in a uniform color at the ceiling in the foyer, 2nd story at west

    Issued 4 Aug 2024Notice sent out 4 Aug 2024Walls and ceilings§ 27-2005

  • Properly repair with similar material the broken or defective wood floor in the 3rd room from east, 2nd story at west

    Issued 4 Aug 2024Notice sent out 4 Aug 2024Floors and stairs§ 27-2005

  • Properly repair with similar material the broken or defective wood floor in the kitchen, 2nd story at west

    Issued 4 Aug 2024Notice sent out 4 Aug 2024Floors and stairs§ 27-2005

  • Properly repair with similar material the broken or defective wood floor in the 2nd room from east at north, 2nd story at west

    Issued 4 Aug 2024Notice sent out 4 Aug 2024Floors and stairs§ 27-2005

  • Properly repair with similar material the broken or defective wood floor in the 4th room from east at south, 2nd story at west

    Issued 4 Aug 2024Notice sent out 4 Aug 2024Floors and stairs§ 27-2005

  • Properly repair with similar material the broken or defective wood floor in the foyer, 2nd story at west

    Issued 4 Aug 2024Notice sent out 4 Aug 2024Floors and stairs§ 27-2005

  • Dept. rules and regulations. remove the encumbrance obstructing egress from fire escapes consiting of flowers pots and house hold items at 4th sty over entrance door to building

    Issued 20 Dec 2023Notice sent out 21 Dec 2023Fire and safety equipment§ 27-2005 +1

  • Properly repair the source and abate the evidence of a water leak at ceiling in the bathroom, 3rd story at south

    Issued 23 Oct 2023Not complied with 21 Nov 2023Leaks and plumbing§ 27-2026

  • Properly secure the loose sink and counter top in the kitchen, 4th story at west

    Issued 12 Oct 2023Notice certified late 20 May 2026Leaks and plumbing§ 27-2005

  • Abate the nuisance consisting of plexi glass at the vestibule door at public hall, 1st story

    Issued 16 Aug 2023Not complied with 21 Nov 2023Doors and windows§ 27-2005 +1

  • Abate the nuisance consisting of plexi glass at the upper and lower window sash at the south wall. at public hall, 3rd story

    Issued 16 Aug 2023Not complied with 21 Nov 2023Doors and windows§ 27-2005 +1

  • Abate the nuisance consisting of plexi glass at the upper and lower window sash at the south wall at public hall, 4th story

    Issued 16 Aug 2023Not complied with 21 Nov 2023Doors and windows§ 27-2005 +1

  • Abate the nuisance consisting of plexi-glass at building entrance door at public hall, 1st story

    Issued 22 Nov 2022Not complied with 21 Nov 2023Doors and windows§ 27-2005 +1

  • Properly repair with similar material the broken or defective fire retardant materials at ceiling at cellar

    Issued 8 Mar 2022Not complied with 21 Nov 2023Walls and ceilings§ 27-2005

  • Replace or repair the self-closing doors that is missing or defective.. in the entrance, 3rd story at east

    Issued 17 Jan 2018Not complied with 21 Nov 2023Fire and safety equipment§ 27-2005 +2

  • Abate the nuisance consisting of wood panel on north, south, east and west walls in the kitchen, 3rd story at east

    Issued 17 Jan 2018Not complied with 21 Nov 2023Walls and ceilings§ 27-2005 +1

  • Properly repair with similar material the broken or defective fire-retarded ceiling. at cellar

    Issued 27 Apr 2001Not complied with 21 Nov 2023Walls and ceilings§ 27-2005

  • Repair the broken or defective plastered surfaces and paint in a uniform color ceiling bathroom 3 sty west an apartment

    Issued 10 Oct 1996Not complied with 21 Nov 2023Walls and ceilings§ 27-2005

  • Abate the nuisance consisting of concealed water leak ceiling bathroom 3 sty west an apartment

    Issued 10 Oct 1996Not complied with 21 Nov 2023Leaks and plumbing§ 27-2005 +1

  • Replace or repair the self-closing doors that is missing or defective 2 sty east an apartment

    Issued 16 Mar 1993First no access to re- inspect violation 21 Nov 2023Fire and safety equipment§ 27-2005 +2

  • Replace or repair the self-closing doors that is missing or defective entrance 2 sty west an apartment.

    Issued 16 Mar 1993First no access to re- inspect violation 21 Nov 2023Fire and safety equipment§ 27-2005 +2

Non-hazardous12 open

Class A. The least serious band: chipped plaster, a missing cabinet, a peeling ceiling in a hallway. The owner has 90 days to correct it.

  • Paint with light colored paint to the satisfaction of this department at ceiling in the bathroom, 2nd story at north

    Issued 4 Aug 2025Notice certified late 20 May 2026Walls and ceilings§ 27-2013

  • Properly repair or replace the broken or defective mailbox of an apartment at public hall, 1st story

    Issued 10 Jun 2025Notice sent out 12 Jun 2025Entry, buzzer and mail§ 27-2005

  • Replace with new the missing the estucheon plate at riser in the 5th room from east at south, 3rd story at west

    Issued 10 Oct 2024Notice sent out 17 Oct 2024§ 27-2005

  • Paint with light colored paint to the satisfaction of this department at ceiling at public hall, 1st story

    Issued 6 Oct 2024Notice sent out 16 Oct 2024Walls and ceilings§ 27-2013

  • Paint with light colored paint to the satisfaction of this department, east wall in the kitchen, 2nd story at west

    Issued 4 Aug 2024Notice sent out 4 Aug 2024Walls and ceilings§ 27-2013

  • Paint with light colored paint to the satisfaction of this department, 1st door from north at east wall, east wall in the foyer, 2nd story at west

    Issued 4 Aug 2024Notice sent out 4 Aug 2024Doors and windows§ 27-2013

  • Paint with light colored paint to the satisfaction of this department, ceiling in the bathroom, 2nd story at west

    Issued 4 Aug 2024Notice sent out 4 Aug 2024Walls and ceilings§ 27-2013

  • Paint with light colored paint to the satisfaction of this department, west wall in the 4th room from east at north, 2nd story at west

    Issued 4 Aug 2024Notice sent out 4 Aug 2024Walls and ceilings§ 27-2013

  • Paint with light colored paint to the satisfaction of this department, east wall in the bathroom, 2nd story at west

    Issued 4 Aug 2024Notice sent out 4 Aug 2024Walls and ceilings§ 27-2013

  • Repair the broken or defective plastered surfaces and paint in a uniform color the ceiling in the bathroom, 3rd story at west

    Issued 21 Nov 2023Notice sent out 23 Nov 2023Walls and ceilings§ 27-2005

Show all 12
  • Paint metal in accordance with dept. regulation the riser in the bathroom, 3rd story at east

    Issued 16 Aug 2023Not complied with 21 Nov 2023Walls and ceilings§ 27-2005

  • File plans and application and legalize the following alteration or restore to the legal condition existing prior to the making of said alteration washbasin & water closet compartment installed cellar rear.

    Issued 16 Mar 1993Not complied with 21 Nov 2023§ 300

Orders and notices1 open

An order issued against the building as a whole rather than a condition in one apartment: a vacate order, or selection for HPD's Alternative Enforcement Program for buildings with persistent violations.

  • The premises has been selected to participate in the alternative enforcement program which may result in building-wide inspections, fees, and extensive repair work to correct violations and underlying conditions. charges for repair work done pursuant to this order, if not paid, will become liens on the property

    Issued 31 Jan 2022First no access to re- inspect violation 16 Aug 2023§ 27-2153

Paperwork and notices12 open

The owner failed to file something the city requires, most often the annual property registration or the annual bedbug report. Real violations, and they say something about an owner, but not a condition anyone is living in. Kept out of the count at the top of this page for that reason.

  • ×3File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.

    3 issued 10 Apr 2024 to 5 May 2026Notice sent outPaperwork and notices

  • ×2File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.

    2 issued 9 Apr 2021 to 23 Mar 2023First no access to re- inspect violationPaperwork and notices

  • Post, in a form approved by the commissioner, and maintain a notice in a common area of the building regarding the procedures that should be followed when a gas leak is suspected

    Issued 20 Dec 2022Not complied with 21 Nov 2023Paperwork and notices§ 27-2005

  • ×2Post and maintain a proper notice on wall of the entrance story in english and spanish on the availability of the agencys housing information guide. a sample notice can be found at www.nyc.gov/hpd. at public hall, 1st story

    2 issued 23 Mar 2018 to 20 Dec 2022Not complied withPaperwork and notices§ 26-1103

  • ×2Post and maintain a proper sign on wall of entrance story showing the registration number assigned by the department and the address of the building. at public hall, 1st story

    2 issued 23 Mar 2018 to 20 Dec 2022Not complied withPaperwork and notices§ 27-2104

  • Post, in a form approved by the commissioner, and maintain a notice in a common area of the building regarding the procedures that should be followed when a gas leak is suspected at public hall, 1st story

    Issued 23 Mar 2018Not complied with 21 Nov 2023Paperwork and notices§ 27-2005

  • Post a proper notice of carbon monoxide detecting device requirements, in a form approved by the commissioner, in a common area of a class a multiple dwelling near inspection certificate or provide notice to tenants in a private dwelling. at public hall, 1st story

    Issued 23 Mar 2018First no access to re- inspect violation 21 Nov 2023Paperwork and notices§ 27-2046.1

156 closed violations, plus 6 closed paperwork filings

Closed means HPD recorded the violation as corrected, or dismissed it. Both appear here, because the difference matters and only HPD’s own status line says which it was.

  • Trace and repair the source and abate the visible mold condition... the ceiling and east wall in the 1st room from east, 3rd story at east original violation 16176647 issued 16-aug-23 has been upgraded to class c per administrative code §27-2017.3a(5)(a) or (b).

    Issued 16 Aug 2023Violation closed 22 Jun 2026Mold and damp§ 27-2017.3

  • Trace and repair the source and abate the visible mold condition... at the ceiling and north wall in the bathroom, 3rd story at east original violation 16176639 issued 16-aug-23 has been upgraded to class c per administrative code §27-2017.3a(5)(a) or (b).

    Issued 16 Aug 2023Violation closed 22 Jun 2026Mold and damp§ 27-2017.3

  • Replace or repair the self-closing doors that is missing or defective building entrance door hinge, 1st story

    Issued 17 Jan 2026Violation closed 20 Apr 2026Fire and safety equipment§ 27-2005 +3

  • Properly repair the source and abate the evidence of a water leak over ceiling in the bathroom, 2nd story at north

    Issued 9 May 2025Violation closed 6 Nov 2025Leaks and plumbing§ 27-2026

  • Trace and repair the source and abate the visible mold condition... less than 10 sqft at ceiling in the bathroom, 2nd story at north

    Issued 10 Jun 2025Violation closed 10 Oct 2025Mold and damp§ 27-2017.3

  • Properly repair and abate unsafe electric wiring condition consisting of exposed electric wires at the ceiling in the 3rd room from east, 2nd story at west

    Issued 4 Aug 2024Violation closed 4 Aug 2025Electrical§ 27-2005

  • Replace with new the missing mortise locking device on door in the entrance, 2nd story at east

    Issued 20 Dec 2022Violation closed 28 Jul 2025Doors and windows§ 27-2005

  • Correct the lead-based paint hazard - paint that tested positive for lead content and that is peeling or on a deteriorated subsurface - using work practices set forth in 28 rcny §11-06(b)(2) 1st door frame from south at west wall, north wall, west wall in the bathroom, 2nd story at west

    Issued 4 Aug 2024Violation closed 13 Nov 2024Lead paint§ 27-2056.6

  • Correct the lead-based paint hazard - paint that tested positive for lead content and that is peeling or on a deteriorated subsurface - using work practices set forth in 28 rcny §11-06(b)(2) south wall in the foyer, 2nd story at west

    Issued 4 Aug 2024Violation closed 13 Nov 2024Lead paint§ 27-2056.6

  • Correct the lead-based paint hazard - paint that tested positive for lead content and that is peeling or on a deteriorated subsurface - using work practices set forth in 28 rcny §11-06(b)(2) 1st door frame from west at north wall, north wall, west wall, 1st window frame from east at south wall in the kitchen, 2nd story at west

    Issued 4 Aug 2024Violation closed 13 Nov 2024Lead paint§ 27-2056.6

  • Correct the lead-based paint hazard - paint that tested positive for lead content and that is peeling or on a deteriorated subsurface - using work practices set forth in 28 rcny §11-06(b)(2) north wall, east wall, west wall, 1st window frame from north at east wall in the 2nd room from east at north, 2nd story at west

    Issued 4 Aug 2024Violation closed 13 Nov 2024Lead paint§ 27-2056.6

  • Properly repair the source and abate the evidence of a water leak at ceiling in the bathroom, 3rd story at south

    Issued 20 Nov 2023Violation closed 23 Jan 2024Leaks and plumbing§ 27-2026

  • Properly repair the source and abate the evidence of a water leak at the ceiling and east wall in the 1st room from east, 3rd story at east

    Issued 16 Aug 2023Violation closed 23 Jan 2024Leaks and plumbing§ 27-2026

  • Properly repair with similar material the broken or defective wood floor in the kitchen, 4th story at west

    Issued 12 Oct 2023Violation closed 21 Nov 2023Floors and stairs§ 27-2005

  • Properly repair or replace the broken or defective rusted metal base cabinet in the kitchen, 4th story at west

    Issued 12 Oct 2023Violation closed 21 Nov 2023Walls and ceilings§ 27-2005

  • Properly repair with similar material the broken or defective roof with 90lbs asphalt roof covering

    Issued 16 Aug 2023Violation closed 21 Nov 2023Roof and outside the building§ 27-2005

  • Repair the broken or defective plastered surfaces and paint in a uniform color the ceiling in the kitchen, 3rd story at east

    Issued 16 Aug 2023Violation closed 21 Nov 2023Walls and ceilings§ 27-2005

  • Repair the broken or defective plastered surfaces and paint in a uniform color the ceiling and east wall in the 1st room from east, 3rd story at east

    Issued 16 Aug 2023Violation closed 21 Nov 2023Walls and ceilings§ 27-2005

  • Replace or repair the self-closing doors that is missing or defective..., 1st story

    Issued 23 Jan 2023Violation closed 21 Nov 2023Fire and safety equipment§ 27-2005 +2

  • Paint with light colored paint to the satisfaction of this department at west wall at public hall stairs, 3rd story

    Issued 8 Mar 2022Violation closed 21 Nov 2023Floors and stairs§ 27-2013

  • Abate the nuisance consisting of exposed electrical wiring clg thru out cellar.

    Issued 16 Mar 1993Violation closed 21 Nov 2023Electrical§ D26-10.01

  • Correct the lead-based paint hazard - paint that tested positive for lead content and that is peeling or on a deteriorated subsurface - using work practices set forth in 28 rcny §11-06(b)(2) west wall in the kitchen, 2nd story at north

    Issued 22 Jul 2021Violation closed 23 Oct 2023Lead paint§ 27-2056.6

  • Correct the lead-based paint hazard - paint that tested positive for lead content and that is peeling or on a deteriorated subsurface - using work practices set forth in 28 rcny §11-06(b)(2) 1st door frame from west at north wall, 1st door frame from east at south wall, north wall, south wall, 1st window frame from south at west wall in the 2nd room from north, 2nd story at north

    Issued 22 Jul 2021Violation closed 23 Oct 2023Lead paint§ 27-2056.6

  • Correct the lead-based paint hazard - paint that tested positive for lead content and that is peeling or on a deteriorated subsurface - using work practices set forth in 28 rcny §11-06(b)(2) 1st window frame from south at west wall in the bathroom, 2nd story at north

    Issued 22 Jul 2021Violation closed 23 Oct 2023Lead paint§ 27-2056.6

  • Correct the lead-based paint hazard - paint that tested positive for lead content and that is peeling or on a deteriorated subsurface - using work practices set forth in 28 rcny §11-06(b)(2) west wall in the 1st room from north at east, 2nd story at north

    Issued 22 Jul 2021Violation closed 23 Oct 2023Lead paint§ 27-2056.6

  • Correct the lead-based paint hazard - paint that tested positive for lead content and that is peeling or on a deteriorated subsurface - using work practices set forth in 28 rcny §11-06(b)(2) 1st door from south at west wall, west wall in the 3rd room from north, 2nd story at north

    Issued 22 Jul 2021Violation closed 23 Oct 2023Lead paint§ 27-2056.6

  • Correct the lead-based paint hazard - presumed lead paint that is peeling or on a deteriorated subsurface using work practices set forth in 28 rcny §11-06(b)(2) ceiling in the 1st room from east at south, 2nd story at east

    Issued 28 May 2021Violation closed 23 Oct 2023Lead paint§ 27-2056.6

  • Correct the lead-based paint hazard - presumed lead paint that is peeling or on a deteriorated subsurface using work practices set forth in 28 rcny §11-06(b)(2) ceiling in the bathroom, 2nd story at east

    Issued 28 May 2021Violation closed 23 Oct 2023Lead paint§ 27-2056.6

  • Correct the lead-based paint hazard - presumed lead paint that is peeling or on a deteriorated subsurface using work practices set forth in 28 rcny §11-06(b)(2) ceiling in the 1st room from east at north, 2nd story at east

    Issued 28 May 2021Violation closed 23 Oct 2023Lead paint§ 27-2056.6

  • Abate the infestation consisting of mice in the entire apartment, 2nd story at east

    Issued 20 Dec 2022Violation closed 18 Oct 2023Pests§ 27-2017.4

  • Abate the infestation consisting of mice at cellar

    Issued 8 Mar 2022Violation closed 18 Oct 2023Pests§ 27-2017.4

  • Abate the nuisance consisting of mice in the entire apartment, 3rd story

    Issued 14 Apr 2010Violation closed 18 Oct 2023Pests§ 27-2018

  • Abate the nuisance consisting of vermin mice and roaches. in the entire apartment -r, 1st story

    Issued 27 Apr 2001Violation closed 18 Oct 2023Pests§ 27-2018

  • Abate the nuisance consisting of vermin mice and roaches throughout 1 sty west an apartment, section '' ''

    Issued 23 Sept 1997Violation closed 18 Oct 2023Pests§ 27-2018

  • Abate the nuisance consisting of vermin mice and roaches thru out 3 sty west an apartment, section '' ''

    Issued 10 Oct 1996Violation closed 18 Oct 2023Pests§ 27-2018

  • Abate the nuisance consisting of vermin mice and roaches thru out 3 sty east an apartment., section '' ''

    Issued 16 Mar 1993Violation closed 18 Oct 2023Pests§ D26-13.03

  • Abate the nuisance consisting of vermin ants & roaches kitchen 3 sty south an apartment.

    Issued 16 Mar 1993Violation closed 18 Oct 2023Pests§ D26-13.03

  • Trace and repair the source and abate the visible mold condition... the ceiling and east wall in the 1st room from east, 3rd story at east

    Issued 16 Aug 2023Violation closed 16 Oct 2023Mold and damp§ 27-2017.3

  • Trace and repair the source and abate the visible mold condition... at the ceiling and north wall in the bathroom, 3rd story at east

    Issued 16 Aug 2023Violation closed 16 Oct 2023Mold and damp§ 27-2017.3

  • Abate the nuisance consisting of hot water exceeding 130 degrees maximum allowable at all fixtures in the entire apartment, 2nd story at east

    Issued 20 Dec 2022Violation closed 11 Oct 2023Heat and hot water§ 27-2005 +1

  • File plans and application and legalize the following alteration or restore to the legal condition existing prior to the making of said alteration wall erected creating storeage room at cellar

    Issued 8 Mar 2022Violation closed 11 Oct 2023Walls and ceilings§ 300

  • Fire egress defective. remove the obstruction in fireproof passageway gate locked at fire passage way

    Issued 8 Mar 2022Violation closed 11 Oct 2023Fire and safety equipment§ 27-2005 +1

  • Properly repair the source and abate the evidence of a water leak at the ceiling in the bathroom, 2nd story at north

    Issued 22 Jul 2021Violation closed 11 Oct 2023Leaks and plumbing§ 27-2026

  • Properly repair the broken or defective electrical outlet at south wall in the 1st room from north at west, 2nd story at north

    Issued 22 Jul 2021Violation closed 11 Oct 2023Electrical§ 27-2005

  • Install the missing or repair/replace the defective window guard(s) in accordance with the specifications of the new york city health code section 24 rcny chapter 12. wg to install = 6; wg to replace = 0; wg to repair = 1; in the entire apartment, 2nd story at north

    Issued 22 Jul 2021Violation closed 11 Oct 2023Fire and safety equipment§ 27-2043.1

  • Repair the broken or defective plastered surfaces and paint in a uniform color the north wall in the kitchen, 2nd story at north

    Issued 22 Jul 2021Violation closed 11 Oct 2023Walls and ceilings§ 27-2005

  • Repair the broken or defective plastered surfaces and paint in a uniform color the ceiling in the 1st room from north at east, 2nd story at north

    Issued 22 Jul 2021Violation closed 11 Oct 2023Walls and ceilings§ 27-2005

  • Paint with light colored paint to the satisfaction of this department the 1st door frame from south at west wall in the 1st room from north at east, 2nd story at north

    Issued 22 Jul 2021Violation closed 11 Oct 2023Doors and windows§ 27-2013

  • Paint with light colored paint to the satisfaction of this department all peeling paint surfaces in the foyer, 2nd story at north

    Issued 22 Jul 2021Violation closed 11 Oct 2023Walls and ceilings§ 27-2013

  • Paint metal in accordance with dept. regulation the 1st riser from east at south wall in the 3rd room from north, 2nd story at north

    Issued 22 Jul 2021Violation closed 11 Oct 2023Walls and ceilings§ 27-2005

  • Repair the broken or defective plastered surfaces and paint in a uniform color the north wall in the 1st room from north at west, 2nd story at north

    Issued 22 Jul 2021Violation closed 11 Oct 2023Walls and ceilings§ 27-2005

  • Repair the broken or defective plastered surfaces and paint in a uniform color the ceiling, west wall, south wall, east wall in the bathroom, 2nd story at north

    Issued 22 Jul 2021Violation closed 11 Oct 2023Walls and ceilings§ 27-2005

  • Replace with new the broken or defective glass panel ( cracked ) at the upper sash of the window at north wall at 1st room from north at west, 2nd story, apartment

    Issued 15 Jul 2021Violation closed 11 Oct 2023Doors and windows§ 27-2005

  • Properly repair the broken or defective electrical outlet on the south wall at 1st room from north at west, 2nd story, apartment

    Issued 15 Jul 2021Violation closed 11 Oct 2023Electrical§ 27-2005

  • Repair the broken or defective plastered surfaces and paint in a uniform color the ceiling in the 1st room from east at north, 2nd story at east

    Issued 28 May 2021Violation closed 11 Oct 2023Walls and ceilings§ 27-2005

  • Repair the broken or defective plastered surfaces and paint in a uniform color the ceiling and east wall in the 1st room from east at south, 2nd story at east

    Issued 28 May 2021Violation closed 11 Oct 2023Walls and ceilings§ 27-2005

  • Replace with new the broken or defective upper sash window glass in window at south in the 1st room from east at south, 2nd story at east

    Issued 28 May 2021Violation closed 11 Oct 2023Doors and windows§ 27-2005

  • Properly repair the broken or defective electrical outlet at west wall in the 1st room from east at south, 2nd story at east

    Issued 28 May 2021Violation closed 11 Oct 2023Electrical§ 27-2005

  • Repair the broken or defective plastered surfaces and paint in a uniform color the ceiling, east and west walls in the bathroom, 2nd story at east

    Issued 28 May 2021Violation closed 11 Oct 2023Walls and ceilings§ 27-2005

  • Paint metal in accordance with dept. regulation steam riser in the bathroom, 2nd story at east

    Issued 28 May 2021Violation closed 11 Oct 2023Heat and hot water§ 27-2005

  • Repair or replace the carbon monoxide detecting device(s). missing in the entire apartment, 2nd story at east

    Issued 28 May 2021Violation closed 11 Oct 2023Fire and safety equipment§ 27-2046.1

  • And dept. rules and regulations. scrape and remove rust scales and paint with 2 coats of paint all parte all story balconies stacks at rear yard at fire escape

    Issued 22 May 2021Violation closed 11 Oct 2023Fire and safety equipment§ 27-2014

  • Paint with light colored paint to the satisfaction of this department the ceiling, 1st door from west at north wall, 1st door frame from west at north wall, 1st window frame from north at east wall, 1st closet from west at north wall door, 2nd closet from west at north wall door, 2nd door frame from west at north wall, 2nd door from west at north wall in the 1st room from east at south, 3rd story at east

    Issued 17 Jan 2018Violation closed 11 Oct 2023Doors and windows§ 27-2013

  • Replace with new the broken or defective sink base, cabinet and counter- top. in the kitchen -r, 1st story

    Issued 27 Apr 2001Violation closed 11 Oct 2023Leaks and plumbing§ 27-2005

  • Properly repair the broken or defective wall cabinets. in the kitchen -r, 1st story

    Issued 27 Apr 2001Violation closed 11 Oct 2023Walls and ceilings§ 27-2005

  • Repair or replace the smoke detector missing, tenants name ms. b. espinal. in the entire apartment -r, 1st story

    Issued 27 Apr 2001Violation closed 11 Oct 2023Fire and safety equipment§ 27-2045

  • Dept. rules and regulations. remove the encumbrance obstructing egress from fire escapes north, and west. at fire escape

    Issued 27 Apr 2001Violation closed 11 Oct 2023Fire and safety equipment§ 27-2005 +1

  • Abate the nuisance consisting of exposed live bx. cable ceiling and walls. at cellar

    Issued 27 Apr 2001Violation closed 11 Oct 2023Walls and ceilings§ 27-2005 +1

  • Properly repair the broken or defective mortise lock, on door. in the entrance -r, 1st story

    Issued 27 Apr 2001Violation closed 11 Oct 2023Doors and windows§ 27-2005

  • Provide bell system for 1 sty west an apartment to vestibule, section '' ''

    Issued 23 Sept 1997Violation closed 11 Oct 2023Entry, buzzer and mail§ 27-2005

  • Repair or replace the smoke detector defective 1 sty west an apartment ms espinal, section '' ''

    Issued 23 Sept 1997Violation closed 11 Oct 2023Fire and safety equipment§ 27-2045

  • Abate the nuisance consisting of broken wood base cabinet south wall kitchen area 1 sty west an apartment, section '' ''

    Issued 23 Sept 1997Violation closed 11 Oct 2023Walls and ceilings§ 27-2005 +1

  • Replace with new the missing showerhead bathtub bathroom 3 sty west an apartment

    Issued 10 Oct 1996Violation closed 11 Oct 2023Leaks and plumbing§ 27-2005

  • Fire egress defective. remove obstructing bars or unlawful gates from window to fire escape or provide approved type gate 3 sty west an apartment

    Issued 10 Oct 1996Violation closed 11 Oct 2023Fire and safety equipment§ 27-2005 +1

  • Replace with new the broken or defective glass lower sash window southwest room 3 sty west an apartment

    Issued 10 Oct 1996Violation closed 11 Oct 2023Doors and windows§ 27-2005

  • Properly repair the broken or defective and make operable window sashes thru out 3 sty west an apartment

    Issued 10 Oct 1996Violation closed 11 Oct 2023Doors and windows§ 27-2005

  • Properly repair the broken or defective bell system vestibule to 3 sty west an apartment

    Issued 10 Oct 1996Violation closed 11 Oct 2023Entry, buzzer and mail§ 27-2005

  • Repair the leaky and/or defective faucets bathtub bathroom 3 sty west an apartment

    Issued 10 Oct 1996Violation closed 11 Oct 2023Leaks and plumbing§ 27-2026

  • Properly repair with similar material the broken or defective bathroom floor cement 4 sty an apartment., section '' ''

    Issued 16 Mar 1993Violation closed 11 Oct 2023Floors and stairs§ D26-10.01

  • Provide ready access to buildings heating system door locked at basement

    Issued 22 Nov 2022Violation closed 27 Sept 2023Heat and hot water§ 27-2033

  • Properly repair with similar material the broken or defective fire retardant materials at west wall at public hall stairs, 3rd story

    Issued 8 Mar 2022Violation closed 27 Sept 2023Floors and stairs§ 27-2005

  • And dept. rules and regulations. scrape and remove rust scales and paint with 2 coats of paint all parts all story balconies stacks at the front of the building at fire escape

    Issued 22 May 2021Violation closed 27 Sept 2023Fire and safety equipment§ 27-2014

  • Dept. rules and regulations. remove the encumbrance obstructing egress from fire escapes flowers pots and household items at 4th story balcony, 2nd satck from north at building west yard at fire escape

    Issued 21 May 2021Violation closed 27 Sept 2023Fire and safety equipment§ 27-2005 +1

  • Install and maintain sufficient light or lights of at least 100 watts incandescent or equivalent each, to light adequately from sunset to sunrise the building front

    Issued 13 Nov 2019Violation closed 27 Sept 2023Electrical§ 27-2040

  • Provide adequate light of not less than 60 watts incandescent or equivalent illumination in the vestibule at public hall, 1st story

    Issued 13 Nov 2019Violation closed 27 Sept 2023Electrical§ 27-2039

  • Post notice, in form approved by the department, stating the name and location of the person designated by the owner to have key to buildings heating system... at public hall, 1st story

    Issued 23 Mar 2018Violation closed 27 Sept 2023Heat and hot water§ 27-2033

  • Dept. rules and regulations. remove the encumbrance obstructing egress from fire escapes 2nd and 3rd sty balconies north building.

    Issued 16 Jul 1997Violation closed 27 Sept 2023Fire and safety equipment§ 27-2005 +1

  • Properly repair with similar material the broken or defective plaster board ceiling east cellar.

    Issued 16 Jul 1997Violation dismissed 27 Sept 2023Walls and ceilings§ 27-2005

  • Provide ready access to buildings heating system door cellar 1 sty public hall locked.

    Issued 20 Nov 1996Violation closed 27 Sept 2023Heat and hot water§ 27-2033

  • Properly repair with similar material the broken or defective plasterboard & cement clg cellar thru out r78.

    Issued 16 Mar 1993Violation dismissed 27 Sept 2023Walls and ceilings§ D26-10.01

  • Provide suitable tight cover for the handhole opening of trap cellar center.

    Issued 16 Mar 1993Violation closed 27 Sept 2023§ D26-16.01

  • Replace with new the broken or defective glass at building entrance door at public hall, 1st story

    Issued 29 Mar 2022Violation closed 16 Aug 2023Doors and windows§ 27-2005

  • Replace or repair the self-closing doors that is missing or defective.. in the entrance, 2nd story at north

    Issued 22 Jul 2021Violation dismissed 16 Aug 2023Fire and safety equipment§ 27-2005 +2

  • Replace or repair the self-closing doors that is missing or defective... in the entrance, 2nd story at east

    Issued 28 May 2021Violation dismissed 16 Aug 2023Fire and safety equipment§ 27-2005 +2

  • Fire escape defective. adjust the dropladder so that it will slide easily in the guide rods at rear yard at fire escape

    Issued 22 May 2021Violation closed 16 Aug 2023Fire and safety equipment§ 27-2005

  • Repair the leaky and/or defective faucets hot water continuously running at bathtub in the bathroom, 3rd story at east

    Issued 17 Jan 2018Violation closed 16 Aug 2023Heat and hot water§ 27-2026

  • Replace with new the broken or defective rain-leader, west yard.

    Issued 27 Apr 2001Violation closed 16 Aug 2023Roof and outside the building§ 27-2005

  • Repair the broken or defective rain leader cellar 1st sty west yard.

    Issued 16 Jul 1997Violation closed 16 Aug 2023Roof and outside the building§ 27-2027

  • Provide an adequate supply of heat for the apartment in the entire apartment, 2nd story at east

    Issued 22 Nov 2022Violation dismissed 12 Feb 2023Heat and hot water§ 27-2029

  • Replace or repair the self-closing doors that is missing or defective apartment in the entrance, 2nd story at east

    Issued 22 Nov 2022Violation dismissed 12 Feb 2023Fire and safety equipment§ 27-2005 +2

Showing the 100 most recent of 156.

250 violations on record in total, 88 of them open. The count at the top of this page counts habitability violations only.

Complaints to the city

Public complaint

Complaints are reports made to the city. They are not confirmed findings. They come from HPD and from 311, and the same problem can appear more than once if more than one neighbour called.

52 complaints in three years, 21 of them in the last twelve months.

  • Leaks and plumbing2 / 12
  • Heat and hot water5 / 7
  • Mold and damp0 / 6
  • Noise2 / 5
  • Pests1 / 5
  • Doors and windows3 / 5
  • Entry, buzzer and mail1 / 4
  • Appliances2 / 2
  • Garbage and cleanliness2 / 2
  • Floors and stairs1 / 2
  • Super and management1 / 1
  • Walls and ceilings1 / 1

Last twelve months / last three years. The solid part of each bar is the last twelve months.

Court records

Court record

Housing Court cases

Cases the city’s housing department (HPD) brought against the owner, usually to force repairs or restore heat. A case is an allegation; where the court recorded an outcome, it is shown.

1 case pending, 1 closed.

  • ComprehensivePending

    Opened 9 May 2023

  • Tenant Action/Harassment

    Opened 6 Jul 2021No harassment found

Evictions

Residential evictions carried out by a city marshal since 2017. Most follow a case for unpaid rent, so a count here is not by itself a finding about the building or the landlord. We show how many, never which apartment.

No marshal evictions recorded at this building since 2017.

Filings

Public filing

Building permits

No DOB permits filed for this building in the last five years.

Annual bedbug report

Every multiple dwelling in New York must file this once a year. A report of zero infested units is good news. No report is not: failing to file is itself a violation.

No bedbug report on file for this building. That usually means the owner did not file one, not that there is nothing to report.

Ownership and management

Public filing

Associations come from registration records and may be incomplete. Owners register with HPD once a year, so a change of hands can go unrecorded for a full cycle.

  • Registered managing agent

    884 HART ST CORP

    Public records list 884 HART ST CORP as the registered managing agent for this address as of 7 May 2026. Source: HPD registration.

  • Owner of record

    884 HART STREET CORP

    Public records list 884 HART STREET CORP as the owner of record for this address as of 7 May 2026. Source: HPD registration.

Wrong company, wrong date, or a change that is not reflected here? Report a correction.

What to ask at the viewing

Drawn from this building’s record above. They are questions, not conclusions: the point is to find out, in the twenty minutes you get inside, what the public record cannot tell you.

  1. The city currently has 25 open immediately-hazardous violations on this building. Ask which apartments they concern, how many are in the one you would be renting, and when HPD re-inspects.
  2. HPD has 1 case pending against the owner in Housing Court (comprehensive). Ask what it is about and whether the work has been done.
  3. There were 5 heat or hot-water complaints here in the last twelve months. Ask who handles heat, how quickly it is usually restored, and whether the boiler has been replaced.
  4. There are 4 open mould violations on record. Ask to look behind furniture and under sinks, and ask what was done the last time; a repaint is not a repair.
  5. Ask what the deposit is, exactly what can be deducted from it, and how and when it comes back.
  6. Ask who to call when something breaks, what happens after hours and at weekends, and how long a repair normally takes.

Ask for anything that matters in writing; an email after the viewing is enough. We are not your lawyer and this is not legal advice.

Questions about this building

BBL 3032360029 · Block 3236, Lot 29 · Building class C7